2010
DOI: 10.1016/j.jim.2010.09.009
|View full text |Cite
|
Sign up to set email alerts
|

Anti-BSA antibodies are a major cause of non-specific binding in insulin autoantibody radiobinding assays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(12 citation statements)
references
References 10 publications
1
11
0
Order By: Relevance
“…The assay was, however, unable to distinguish between the IA + and IA - donors with many samples producing high ECL signal independent of antibody status (Figure 7). This result was not entirely unexpected as others have reported non-specific interfering factors when assessing IAA in human samples [29]. As ECL-based assays have previously been successfully used in human plasma and serum samples for other analytes, we were confident that the ECL platform could still allow for the sensitive detection of human antibodies against insulin.…”
Section: Resultssupporting
confidence: 72%
See 1 more Smart Citation
“…The assay was, however, unable to distinguish between the IA + and IA - donors with many samples producing high ECL signal independent of antibody status (Figure 7). This result was not entirely unexpected as others have reported non-specific interfering factors when assessing IAA in human samples [29]. As ECL-based assays have previously been successfully used in human plasma and serum samples for other analytes, we were confident that the ECL platform could still allow for the sensitive detection of human antibodies against insulin.…”
Section: Resultssupporting
confidence: 72%
“…Clarification of human samples with SA-beads to remove non-specifically bound materials significantly decreased background while maintaining specific signal. This clearance step overcomes challenges present in the RBA where assay components including BSA [29] reduce the specificity of that IA assay format. The ECL assay requires the same sample volume per well used in RBA but does not require the generation of a standard curve using known positive samples (Table 3) [30].…”
Section: Discussionmentioning
confidence: 99%
“…5,29,30 It may be higher in areas of low endemicity, with an antibody that is less specific to anti-PGL-1. In this context, a factor that can be investigated concerns the consumption of bovine and, as is well-known, Rio Grande do Sul consumes the most in Brazil.…”
Section: Discussionmentioning
confidence: 99%
“…Anti-BSA antibodies present in human sera react with minor contaminants such as BSA in insulin preparations [7].…”
Section: Non-specific Reactions Involved In Indirect Elisamentioning
confidence: 99%