1968
DOI: 10.1259/0007-1285-41-492-951
|View full text |Cite
|
Sign up to set email alerts
|

Anoxia in radiobiology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

1972
1972
2002
2002

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…The 0 2 concentration in the effluent gas from the chamber was monitored using a Thermox I analyser (Thermolab Instruments, Inc ., Pennsylvania) . It has been shown that polystyrene Petri dishes hold 0 2 in solution and release it slowly by diffusion, resulting in a build-up of 0 2 concentration around the cells attached to the plastic surface (Chapman, Sturrock, Boag and Crookall 1970) . Based on calculations using values for solubility and diffusion coefficient reported by Chapman et al (1970), it was found that the concentrations of 0 2 at the cell surface in contact with the polystyrene disc was 0 .…”
Section: Methodsmentioning
confidence: 99%
“…The 0 2 concentration in the effluent gas from the chamber was monitored using a Thermox I analyser (Thermolab Instruments, Inc ., Pennsylvania) . It has been shown that polystyrene Petri dishes hold 0 2 in solution and release it slowly by diffusion, resulting in a build-up of 0 2 concentration around the cells attached to the plastic surface (Chapman, Sturrock, Boag and Crookall 1970) . Based on calculations using values for solubility and diffusion coefficient reported by Chapman et al (1970), it was found that the concentrations of 0 2 at the cell surface in contact with the polystyrene disc was 0 .…”
Section: Methodsmentioning
confidence: 99%
“…75 ml) was held in the meniscus, and the depth of medium over 90 per cent of the surface area was less than 100 µm . Consequently, in this experimental system the oxygen concentration in the cellular layer was expected to follow closely the oxygen concentration of the gas phase, since the rate-constant determining the flow of oxygen out of the liquid layer was several times the rate-constant determining the exponential dilution of oxygen in the gas phase by the incoming gas (see equation (3), Chapman, Sturrock, Boag and Crookall 1970) . Unless otherwise specified, the dishes were gassed for 5 min before, and during, the radiation treatment .…”
Section: Methodsmentioning
confidence: 99%
“…In the present study, the use of hypoxic cells required treatment in glass flasks (Chapman, Sturrock, Boag and Crookall 1970) . However, both plating efficiency and responses to irradiation or 42°C hyperthermia for aerobic cells were the same, independently of cells being treated in glass or plastic flasks .…”
Section: Treatment Under Hvpoxic Conditionsmentioning
confidence: 99%