2015
DOI: 10.15627/jd.2015.6
|View full text |Cite
|
Sign up to set email alerts
|

Annual Performance Assessment of Complex Fenestration Systems in Sunny Climates Using Advanced Computer Simulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…Beside reflective gratings as shown in Figure 2, refractive prismatic systems can be applied, e.g., as micro-structures, which originally were developed to improve the daylighting of deep rooms. Application and production-related variations are described in [4,5,6,7,8]. These micro-structures can also be used for the redirection of direct and diffuse solar radiation in the visible and infrared spectrum onto the rear surface of bifacial PV modules as shown in Figure 1.…”
Section: Micro-structured Redirection Of Solar Radiationmentioning
confidence: 99%
“…Beside reflective gratings as shown in Figure 2, refractive prismatic systems can be applied, e.g., as micro-structures, which originally were developed to improve the daylighting of deep rooms. Application and production-related variations are described in [4,5,6,7,8]. These micro-structures can also be used for the redirection of direct and diffuse solar radiation in the visible and infrared spectrum onto the rear surface of bifacial PV modules as shown in Figure 1.…”
Section: Micro-structured Redirection Of Solar Radiationmentioning
confidence: 99%
“…The illumination of rooms by redirected sunlight can be calculated for defined solar positions at a specific time of the year and day [20]. Simulation tools like DIALux or RELUX use bidirectionally measured data [18] of sunlight redirecting systems.…”
Section: Illuminance and Energy Saving In Sunlit Roomsmentioning
confidence: 99%
“…Moreover, the new international standard for daylighting, CEN EN 17037, Daylight of Buildings [15], defines recommendations of daylight provision as well as calculation methods of their assessment. Target illuminances of 300, 500, and 750 lx can be calculated by validated software for Daylight factors [16,17] or for illuminance levels using climate data for a given site and an adequate time step [18][19][20]. As the Daylight factor is based on covered sky conditions, the method using climate data is applied for daylighting by direct sunlight (clear sky conditions).…”
Section: Introductionmentioning