2021
DOI: 10.1016/j.colsurfb.2021.111890
|View full text |Cite
|
Sign up to set email alerts
|

Anion species-triggered antibody separation system utilizing a thermo-responsive polymer column under optimized constant temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 55 publications
0
8
1
Order By: Relevance
“…In reversed-phase LC, a serum sample must be deproteinated before it is injected into a high-performance LC (HPLC) column to prevent the adsorption of serum proteins, which can cause column clogging, onto the beads in the column. In contrast, previous reports revealed that PNIPAAm copolymers without ionic group-modified bead-packed columns eluted proteins without column clogging because non-ionic PNIPAAm copolymers did not show adsorption of the proteins 48 55 . Thus, the elution behavior of the serum–drug samples was observed on the prepared bead-packed column (Fig.…”
Section: Resultscontrasting
confidence: 68%
“…In reversed-phase LC, a serum sample must be deproteinated before it is injected into a high-performance LC (HPLC) column to prevent the adsorption of serum proteins, which can cause column clogging, onto the beads in the column. In contrast, previous reports revealed that PNIPAAm copolymers without ionic group-modified bead-packed columns eluted proteins without column clogging because non-ionic PNIPAAm copolymers did not show adsorption of the proteins 48 55 . Thus, the elution behavior of the serum–drug samples was observed on the prepared bead-packed column (Fig.…”
Section: Resultscontrasting
confidence: 68%
“…Ordinarily, drug concentration must be determined in serum, and deproteination of the serum sample (by the addition of organic solvent) is required before HPLC column injection to avoid serum protein adsorption onto the beads in the column resulting in the column clogging. Thermoresponsive ionic copolymers composed of NIPAAm and ionic monomers have been shown to adsorb proteins via multiple hydrophobic and electrostatic interactions 51 58 . In contrast, the PNIPAAm homopolymer modified-bead packed column scarcely adsorbs proteins even at high column temperatures 51 , 52 .…”
Section: Resultsmentioning
confidence: 99%
“…Polymer-modified silica beads, which were used as packing materials, were prepared by initiator modification via condensation, followed by radical polymerization of the functional monomers for polymer modification (Fig. 1 A) 61 63 . First, N -ethoxycarbonyl-2-ethoxy-1,2-dihydroquinoline (6.18 g, 25.0 mmol) and V-501 (3.50 g, 12.5 mmol) were dissolved in 25 mL of N,N -dimethylformamide (DMF) in a 100 mL flask.…”
Section: Methodsmentioning
confidence: 99%