1984
DOI: 10.1001/archsurg.1984.01390220060013
|View full text |Cite
|
Sign up to set email alerts
|

Aneurysms of a Double Velour Aortic Graft

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

1988
1988
2014
2014

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(11 citation statements)
references
References 6 publications
0
11
0
Order By: Relevance
“…Notwithstanding certain advantages over both woven and weft knitted grafts, problems with warp knits still persist. 1,46,11,12,26,33 In accordance with recommended practices, manufacturers perform lot-to-lot testing of grafts to ensure uniformity of the following performance and construction characteristics: Studies have shown that commercial prostheses have initial bursting strengths between 10 and 50 times greater than that of a normal artery; thus, the initial strength of Dacron prostheses is not a problem. ~1'3 On the other hand, there is a progressive loss in bursting strength (about 2% annually) of Dacron arterial grafts with increasing times of implantation in humans.…”
Section: Discussionmentioning
confidence: 99%
“…Notwithstanding certain advantages over both woven and weft knitted grafts, problems with warp knits still persist. 1,46,11,12,26,33 In accordance with recommended practices, manufacturers perform lot-to-lot testing of grafts to ensure uniformity of the following performance and construction characteristics: Studies have shown that commercial prostheses have initial bursting strengths between 10 and 50 times greater than that of a normal artery; thus, the initial strength of Dacron prostheses is not a problem. ~1'3 On the other hand, there is a progressive loss in bursting strength (about 2% annually) of Dacron arterial grafts with increasing times of implantation in humans.…”
Section: Discussionmentioning
confidence: 99%
“…Intrinsic graft failure has been defined as the inability of a graft to maintain its structural integrity while in the environment of the host tissues [6]. Intrinsic graft failure may assume one of the several clinical forms: delayed interstitial haemorrhage, generalised graft dilatation (early and late) and aneurysm formation with or without perforation [5]. Aneurysmal dilatation of knitted dacron grafts has been studied in vitro by several authors [7,8] who concluded that yarn slippage occurs early after implantation and a second stage failure is related to the characteristic behaviour of individual fibres subjected to load.…”
Section: Case Reportmentioning
confidence: 99%
“…Dacron is the most popular prosthetic material used in vascular surgery. Although anastomotic false aneurysms occur occasionally, rupture and true aneurysm formation of a prosthetic graft is an extremely rare event [1][2][3][4][5] and most reported cases have involved grafts no longer in use. The exact reason for this complication in modern grafts is difficult to ascertain but may include fabrication flaws, faulty preoperative handling as related to methods of sterilization, intra-operative damage, bio-deterioration related to hematomas or infection, and mechanical or structural fatigue.…”
Section: Introductionmentioning
confidence: 99%
“…An M A has been described as a focal or general dilatation following vascular reconstruction due to the leakage of blood through the anastomosis between the prosthetic graft and the host artery [7,8]. The etiology of false aneurysms is associated with a number of different factors, including structural defects in the prostheses, the condition and degeneration of the host artery at the anastomosis, suture and suture-line failure, the method of implantation, and the mechanical forces acting at the anastomotic sites [9,10].…”
Section: Dadgar Et Almentioning
confidence: 99%