1995
DOI: 10.1016/s0016-5107(95)70085-4
|View full text |Cite
|
Sign up to set email alerts
|

Anatomy of the thoracic duct: an endosonographic study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2004
2004
2019
2019

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 2 publications
0
8
0
Order By: Relevance
“…This current study carries forward a concept earlier proposed by our group 8,9 but differs from the earlier experiments because of the use of EUS alone (without contrast injections into lymphatic system) to localize the thoracic duct, use of a 25-gauge needle to puncture, and later monitoring animals for complications, in order to establish safety of this procedure. One of the theoretical hurdles in application of this technique in human subjects may be that aspiration of lymph is a very difficult process (in both animals and humans) because of the low basal flow rate of lymph in the thoracic duct (0.93 mL/ minute in a human fistula study 11 ).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…This current study carries forward a concept earlier proposed by our group 8,9 but differs from the earlier experiments because of the use of EUS alone (without contrast injections into lymphatic system) to localize the thoracic duct, use of a 25-gauge needle to puncture, and later monitoring animals for complications, in order to establish safety of this procedure. One of the theoretical hurdles in application of this technique in human subjects may be that aspiration of lymph is a very difficult process (in both animals and humans) because of the low basal flow rate of lymph in the thoracic duct (0.93 mL/ minute in a human fistula study 11 ).…”
Section: Discussionmentioning
confidence: 99%
“…EUS was performed with a linear echoendoscope (model GF-UC 30P; Olympus America Corp., Melville, NY). The thoracic duct was identified by the previously described technique, 8 with the difference that no contrast medium was injected for fluoroscopic localization of thoracic duct and that it was done using EUS alone. A 25-gauge needle (Echotip Cook Medical Inc., Winston Salem, NC) was used to puncture the thoracic duct.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The TDD was measured by EUS in the mediastinum by the procedure already described by the authors. 4,5 This initial TDD measurement taken at the beginning of the procedure was considered as the baseline TDD. …”
Section: Exclusion Criteriamentioning
confidence: 99%
“…in 1995. 4 More recently, additional studies have been performed to demonstrate the feasibility and safety of EUS-guided TD puncture in swine models by the members of our group. 5,6 Even though the TD has been punctured by EUS, the actual process of lymph aspiration is difficult because the basal lymphatic flow through the TD is very slow (0.93 mL/minute in a human fistula study 7 ).…”
Section: Introductionmentioning
confidence: 99%