Anatomy of the Cun Position at Wrist and Its Application in Pulse Diagnosis

Abstract: Information on anatomy of the Cun position at wrist is lacking; whether the blood vessel taking pulse in Cun is the radial artery or the superficial palmar branch is also clinically controversial. The objective was to investigate the boundaries and contents, and the vascular distribution and their pulse points in Cun. Thirty-two upper extremities of 16 human cadavers were investigated for dissection and observation. The boundaries, contents, and blood vessel distribution in Cun were observed; the location of p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 14 publications
(19 reference statements)
0
6
0
Order By: Relevance
“…The pulse wave velocity was calculated at each peak time (Equation 1). The pulse wave velocity was calculated from the rst peak of the pulse wave recorded at each sensor according to Equation (1). Figure 11 shows a comparison of the pulse wave velocities between pre-test, during test, and post-test conditions of the calculation task, obtained from the pulse diagnosis device.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The pulse wave velocity was calculated at each peak time (Equation 1). The pulse wave velocity was calculated from the rst peak of the pulse wave recorded at each sensor according to Equation (1). Figure 11 shows a comparison of the pulse wave velocities between pre-test, during test, and post-test conditions of the calculation task, obtained from the pulse diagnosis device.…”
Section: Resultsmentioning
confidence: 99%
“…In modern medicine, pulse wave velocity is regarded as an important parameter representing arterial stiffness for quantitatively diagnosing the extent of arteriosclerosis [9][10][11][12][13][14][15]. In traditional pulse diagnosis, the degree of transmission of smooth pulse waves and rough pulse waves are determined [1,2]. In the proposed pulse diagnosis system, the three high-precision pressure sensors arranged in series on the radial artery allow physical measurement of pulse waves directly, and a matrixed acceleration pulse waveform can be obtained.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Then the sensor array (PPS SN7798) were fixed in left-hand-side "guan" site of the wrist. [16] ( Figure 6) The real-time pulse waves of 30 seconds were carried out. Record the amplitude of three characteristic peaks and one valley in pulse waveform.…”
Section: Pulse Wave Acquisition Methodsmentioning
confidence: 99%