2007
DOI: 10.1177/0363546507304137
|View full text |Cite
|
Sign up to set email alerts
|

Anatomical Limitations of Transtibial Drilling in Anterior Cruciate Ligament Reconstruction

Abstract: If tunnels centered in the anterior cruciate ligament attachment sites are desired with the transtibial drilling technique, then a short tibial tunnel is necessary. A short tibial tunnel may compromise graft fixation and graft incorporation, or it may result in a tunnel length-graft length mismatch. An alternative drilling strategy might be employed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

4
237
0
8

Year Published

2009
2009
2017
2017

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 243 publications
(249 citation statements)
references
References 37 publications
4
237
0
8
Order By: Relevance
“…Anatomic placement is considered optimal to provide maximum stability. Traditionally, femoral tunnel drilling has been done through a previously drilled tibial tunnel [1,11,23,26]; however, the results of this approach have sometimes been disappointing because a more vertical graft could limit rotational stability [37,45]. Some have therefore suggested that the femoral tunnel be created independently of the tibial tunnel through the use of an anteromedial drilling portal [8,13,20].…”
Section: Introductionmentioning
confidence: 99%
“…Anatomic placement is considered optimal to provide maximum stability. Traditionally, femoral tunnel drilling has been done through a previously drilled tibial tunnel [1,11,23,26]; however, the results of this approach have sometimes been disappointing because a more vertical graft could limit rotational stability [37,45]. Some have therefore suggested that the femoral tunnel be created independently of the tibial tunnel through the use of an anteromedial drilling portal [8,13,20].…”
Section: Introductionmentioning
confidence: 99%
“…The direct relationship between the drill-guide angle and surgical outcome has not been established. A small drillguide angle may damage tissues adjacent to the tunnel aperture [9], reduce the graft-tunnel bonding [7], attenuate the bone between the tunnel roof and tibial plateau, and cause micro-fracture trauma in the subchondral bone [8]. Conversely, a large drill-guide angle led to a long bone tunnel, which may mismatch the graft length and cause a great bone removal.…”
Section: Discussionmentioning
confidence: 99%
“…A small drill-guide angle reduced the graft-tunnel bonding [7], attenuated the bone between the tibial plateau and tunnel roof, and might cause micro-fracture in the tibial plateau [8].…”
mentioning
confidence: 99%
“…Controversy exists as to whether anatomical tunnel placement can be achieved using a transtibial tunnel drilling [80].…”
Section: Anatomical Single Bundle Techniquesmentioning
confidence: 99%