“…The mass list with a signal to noise ratio of > 5 of each mass spectrum was generated by Data Analysis V4.5 and imported into Composer software (Sierra Analytics, Pasadena, California, USA) for the assignment of chemical formulas. 52 With an error range of 0.5 ppm, the most likely elemental composition of each monoisotopic mass peak was calculated according to the d e t e r m i n e d a c c u r a t e m a s s w i t h i n t h e r a n g e o f C 1−100 H 1−200 N 0−3 O 0−3 S 0−3 . Then, in order to achieve an overview of the compound distributions, all the assigned chemical formulas were divided into molecular classes (i.e., HC, S 1 , S 2 , O, N, etc.)…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The mass list with a signal to noise ratio of > 5 of each mass spectrum was generated by Data Analysis V4.5 and imported into Composer software (Sierra Analytics, Pasadena, California, USA) for the assignment of chemical formulas. 52 With an error range of 0.5 ppm, the most likely elemental composition of each monoisotopic mass peak was calculated according to the d e t e r m i n e d a c c u r a t e m a s s w i t h i n t h e r a n g e o f C 1−100 H 1−200 N 0−3 O 0−3 S 0−3 . Then, in order to achieve an overview of the compound distributions, all the assigned chemical formulas were divided into molecular classes (i.e., HC, S 1 , S 2 , O, N, etc.)…”
Section: Methodsmentioning
confidence: 99%
“…Raw data were further recalibrated during data analysis using a set of homologous alkylated compounds for each sample. The mass list with a signal to noise ratio of > 5 of each mass spectrum was generated by Data Analysis V4.5 and imported into Composer software (Sierra Analytics, Pasadena, California, USA) for the assignment of chemical formulas . With an error range of 0.5 ppm, the most likely elemental composition of each monoisotopic mass peak was calculated according to the determined accurate mass within the range of C 1–100 H 1–200 N 0–3 O 0–3 S 0–3 .…”
Section: Methodsmentioning
confidence: 99%
“…Vulcanized rubber powder is basically insoluble in toluene, and the soluble part increases after desulfurization (S-S/C-S). e swelling and degradation of rubber can be evaluated by quantitatively analyzing the volume and mass loss of toluene insoluble matter (TIM) [19,20]. During CRMA processing, after reaching the specified time each time, without affecting the stirring, the CRMA with a certain mass (M 0 ) was directly weighed out twice: Part a and Part b.…”
Section: Degradation and Swelling Of Crumb Rubbermentioning
confidence: 99%
“…Oil resins; 256 Molecular structures of asphaltenes; 7 Vanadyl porphyrins; 257,258 Polycyclic aromatic hydrocarbons (PAHs); 58,[259][260][261][262][263] Molecular weight distribution of kerogen 264 Heavy Oils and Vacuum Residua; 7,51,[265][266][267][268][269] Asphaltenes; 7,[270][271][272] Petroleum Porphyrin; 7,55,273 Biofuel Research; 7 Molecular weight of pitches; 263,[274][275][276][277][278][279][280][281][282][283] Naphthenic acids; 284,285 Well suited to heaviest samples. Aggregation, low shot-by-shot reproducibility, sample preparation requirements.…”
Section: Maldi (Matrix Assisted Laser Desorption Ionization)mentioning
confidence: 99%