2007
DOI: 10.1016/j.enconman.2007.04.022
|View full text |Cite
|
Sign up to set email alerts
|

Analytical solution of thermal resistance of vapor chamber heat sink with and without pillar

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…However, the thermal performance worsens as the thermal resistance increases. The spreading thermal resistance R s of the heat sink is the resistance that is encountered when the heat is transferred from the heating element, which has a smaller area, through the base plate of the heat sink, which has a larger area, to the top surface of the base plate [4]. The convective thermal resistance R c of the heat sink, which is the resistance that is encountered when the heat is transferred from the top surface of the base plate through the heat sink to the cooling air, is given by…”
Section: Experimental Apparatus and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the thermal performance worsens as the thermal resistance increases. The spreading thermal resistance R s of the heat sink is the resistance that is encountered when the heat is transferred from the heating element, which has a smaller area, through the base plate of the heat sink, which has a larger area, to the top surface of the base plate [4]. The convective thermal resistance R c of the heat sink, which is the resistance that is encountered when the heat is transferred from the top surface of the base plate through the heat sink to the cooling air, is given by…”
Section: Experimental Apparatus and Methodsmentioning
confidence: 99%
“…The surface temperature distribution of the vapor chamber was more uniform than the metal plate and less sensitive to the heat source size and the input power. Hsieh et al [4,5] presented analytical and experimental results concerning the thermal performance of a vapor chamber. They concluded that a vapor chamber without a pillar outperformed one with a pillar, and that the vapor chamber is a favorable alternative to the traditional solid metal heat sink.…”
Section: Introductionmentioning
confidence: 99%
“…While these models only predict steady state performance, and do not capture spatial flow characteristics and operating limits, they enable first-order design for multiple working fluids and different power dissipation levels, and selection of favorable vapor chamber form factors [95], at reasonable accuracy compared to complex, three-dimensional analytical solutions [96]. Additional predictive capabilities can be incorporated into these modeling schemes as necessary.…”
Section: Analytical Modeling Approachesmentioning
confidence: 99%
“…The heat transfer characteristics of the vapor chamber have been widely studied by researchers. Hsieh et al [1] analyzed the thermal resistance of vapor chamber heat sink with and without pillar for electronic cooling. Hu and Tang [2] investigated the flow and thermal characteristics of a microphase-change cooling system with a microgroove evaporator.…”
Section: Introductionmentioning
confidence: 99%