1989
DOI: 10.1016/s0021-9673(01)96448-9
|View full text |Cite
|
Sign up to set email alerts
|

Analytical resolution of 4(5)-alkylated γ(δ)-lactones by high-performance liquid chromatography on a silica-bonded chiral polyacrylamide sorbent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

1990
1990
2010
2010

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 29 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…The ChiraSpher column is stable under aqueous RP and apolar normal phase (NP) conditions; it has been used for resolution of homologous chiral lactones [11,12] and flavanones [13] under NP conditions with a hexane-2-propanol-dioxane mixture as mobile phase. Methanol was added to the eluent to coat the flee OH groups of the ChiraSpher silica gel support [12].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The ChiraSpher column is stable under aqueous RP and apolar normal phase (NP) conditions; it has been used for resolution of homologous chiral lactones [11,12] and flavanones [13] under NP conditions with a hexane-2-propanol-dioxane mixture as mobile phase. Methanol was added to the eluent to coat the flee OH groups of the ChiraSpher silica gel support [12].…”
Section: Introductionmentioning
confidence: 99%
“…Methanol was added to the eluent to coat the flee OH groups of the ChiraSpher silica gel support [12]. Benzoic acid amide derivatives have been successfully resolved under NP conditions on ChiraSpher, the effect of residual silanol groups being minimized by addition of 0.1% v/v diethylamine to the heptane-dioxane mobile phase [14].…”
Section: Introductionmentioning
confidence: 99%
“…Pure (1s) and (1R) enantiomers of 1 (500 mg each) were obtained by preparative HPLC of the product mixture on silica gel (Lichrospher SI 100; 5 pm; 250 x 16 mm; Knauer, Berlin, Germany) using cyc1ohexane:tert-butyl methyl ether (1: 1) as eluent (7.5 mL/min) and UV detection (254 nm). The determination of the optical rotation of the optical antipodes of 1 was achieved by on-line HPLC/ChiraMonitor detection (ACS ChiraMonitor, Zinsser, Frankfurt, Germany) on Hibar Chiraspher (RT 250-4mm; 250X4mm; 5pm; Merck, Darmstadt, Germany) using n-hexane as eluent (0.8 mL/min) (Huffer and Schreier, 1989;Bernreuther et al, 1990).…”
Section: Methodsmentioning
confidence: 99%
“…The run times are often long, reaching up to 1 h. The herein CCC method could be developed for industrial purpose, and it is therefore important for industries to have at their disposal convenient and fast methods to check the purity of massoia lactone. The few HPLC methods used to analyse such lactones are mainly based on chiral analysis, and use specific expensive phases [25,26]. A new, simple and ultra-fast method was developed for the analysis and separation of the three target massoia lactones, using UHPLC.…”
Section: Uhplc-uv/dad-hrms Analysis Of Massoia Lactonesmentioning
confidence: 99%