2013
DOI: 10.1016/j.sab.2013.07.004
|View full text |Cite
|
Sign up to set email alerts
|

Analytical possibilities of different X-ray fluorescence systems for determination of trace elements in aqueous samples pre-concentrated with carbon nanotubes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
14
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(17 citation statements)
references
References 14 publications
3
14
0
Order By: Relevance
“…This increased signal strength greatly influences the detection sensitivities of various elements in TXRF excitation. The minimum detection limits (MDLS) obtained for different elements using the formalism These findings are consistent with the experimental observations reported by Margui 15 . They showed that the quantification of Cadmium in 100mL aqueous samples in the range of 1-20 µg is only practicable by using polarized energy dispersive x-ray fluorescence instrument (P-EDXRF) in contrast to the conventional EDXRF and WDXRF spectrometer.…”
Section: Methodssupporting
confidence: 90%
“…This increased signal strength greatly influences the detection sensitivities of various elements in TXRF excitation. The minimum detection limits (MDLS) obtained for different elements using the formalism These findings are consistent with the experimental observations reported by Margui 15 . They showed that the quantification of Cadmium in 100mL aqueous samples in the range of 1-20 µg is only practicable by using polarized energy dispersive x-ray fluorescence instrument (P-EDXRF) in contrast to the conventional EDXRF and WDXRF spectrometer.…”
Section: Methodssupporting
confidence: 90%
“…Furthermore, the surface area of the graphene oxide nanosheets loaded on the filter plays also an important role for obtaining good sensitivity. It was previously demonstrated [24,25] that if the area of the sample is good fitted to the focal spot size, a bigger fraction of the adsorbed elements are excited and, as a consequence, better sensitivity can be obtained. For this reason, a commercially available vacuum filter assembly of 22-mm diameter size was replaced with one of 5 mm diameter.…”
Section: Resultsmentioning
confidence: 99%
“…Now the materials, functionalized graphene or CNT, having greater surface area and also charge on it are suitable for the electrodeposition of the HMIs. Apart from these qualities, defects introduced during the functionalization process and their inherent good electrical conductivity have the added advantage for this application [25][26][27]. Likewise, nanomaterials other than carbon substrate can also be used.…”
Section: Electrochemical Adsorptionmentioning
confidence: 99%