2017
DOI: 10.1684/abc.2016.1203
|View full text |Cite
|
Sign up to set email alerts
|

Analytical performances of Optilite® turbidimeter (The Binding Site): a new dedicated analyser for specific proteins determination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0
1

Year Published

2018
2018
2019
2019

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 0 publications
0
3
0
1
Order By: Relevance
“…samples with previously demonstrated antigen excess when assayed by Freelite on BNII [6][7][8][9]. In studies performed at UZ Brussel and Pitié-Salpêtrière, Optilite failed to detect antigen excess in 1/8 and 0/3 [7] κ and 1/1 and 1/3 [7] λ cases of antigen excess with Freelite on BNII, respectively. In previous studies, N Latex Siemens antigen detection systems did not fail to detect antigen excess in 19 κ (13 [6], 4 [8], 2 [9]) and 16 λ [6] selected samples with antigen excess when assayed by Freelite on a BN system [6,8,9].…”
mentioning
confidence: 78%
See 2 more Smart Citations
“…samples with previously demonstrated antigen excess when assayed by Freelite on BNII [6][7][8][9]. In studies performed at UZ Brussel and Pitié-Salpêtrière, Optilite failed to detect antigen excess in 1/8 and 0/3 [7] κ and 1/1 and 1/3 [7] λ cases of antigen excess with Freelite on BNII, respectively. In previous studies, N Latex Siemens antigen detection systems did not fail to detect antigen excess in 19 κ (13 [6], 4 [8], 2 [9]) and 16 λ [6] selected samples with antigen excess when assayed by Freelite on a BN system [6,8,9].…”
mentioning
confidence: 78%
“…Most previous studies investigated antigen excess on Siemens or Beckman analyzers without antigen excess detection for Freelite reagents [3][4][5]. Only few data are available on the performance of antigen excess detection using Freelite on SPA Plus [6] or Optilite [7] [Vercammen, Optilite Seed Site Meeting, Birmingham March 2016] and on BN systems using N Latex [6,8,9]. In the current study, we evaluated whether and to what extent the Freelite FLC assay applied on automated Optilite instrument and the N Latex assay applied on a BN system suffer from antigen excess.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Les kits de dosage des fractions C3 et C4 sont quant à eux calibrés par rapport au matériel de référence ERM-DA470k/IFCC, développé pour l'harmonisation du dosage des protéines [13]. Les performances de l'automate Optilite ® pour le dosage des fractions C3 et C4 ont déjà été décrites précédemment [14], et la validation du dosage du C1-inhibiteur a fait l'objet d'une publication récente [15]. Selon notre expérience, les coefficients de variation (CV) de répétabilité et de fidélité intermédiaire sont respectivement inférieurs à 3,0 et 5,0 % pour les 4 paramètres.…”
Section: Méthodes De Dosage Et Réactifsunclassified