1988
DOI: 10.1093/clinchem/34.8.1594
|View full text |Cite
|
Sign up to set email alerts
|

Analytical performance of three commercially available nephelometers compared for quantifying proteins in serum and cerebrospinal fluid.

Abstract: We investigated the analytical performance and imprecision of three commercially available nephelometers for the quantification of various proteins in pooled serum and cerebrospinal fluid. Albumin, transferrin, IgG, IgA, and IgM in serum were determined nephelometrically (BNA, Behring; Array, Beckman) and turbidimetrically (Cobas Bio, Hoffmann-La Roche). All these proteins in cerebrospinal fluid except transferrin were determined nephelometrically with all three systems. CVs and lower limits of detection were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

1989
1989
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(14 citation statements)
references
References 0 publications
1
13
0
Order By: Relevance
“…Our evaluation revealed within-run and total precision performance that was equivalent or superior to the existing commercial nephelometric and turbidimetric immunoassays (23,24). We found the assays to be linear over the calibration range and the analytical sensitivity consistent with previously described findings for serum proteins (7).…”
Section: Discussionsupporting
confidence: 83%
“…Our evaluation revealed within-run and total precision performance that was equivalent or superior to the existing commercial nephelometric and turbidimetric immunoassays (23,24). We found the assays to be linear over the calibration range and the analytical sensitivity consistent with previously described findings for serum proteins (7).…”
Section: Discussionsupporting
confidence: 83%
“…All analyses were performed on the 2nd-4th ml of CSF after lumbar puncture. For every patient albumin levels were measured as part of the diagnostic work-up in cell-free CSF and paired serum samples by immunochemical nephelometry with the Beckman Array Protein System or IMMAGE 800 Immunochemistry System (Beckman Instruments, Fullerton, CA, USA) according to the procedure of Salden [20]. Albumin quotient was calculated to disclose B-CSF-B dysfunction according to the formula: QAlb = [Alb]CSF/[Alb]serum × 1000.…”
Section: Methodsmentioning
confidence: 99%
“…CSF and serum IgG levels were measured by immunochemical nephelometry with the Beckman Immage 800 Immunochemistry System (Beckman Instruments, Inc. Fullerton, CA. USA) according to the procedure of Salden et al [ 56 ].…”
Section: Methodsmentioning
confidence: 99%