Analytical performance monitoring of a 142.5kWp grid-connected rooftop BIPV system in Singapore

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
45
2
1

Year Published

2013
2013
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 136 publications
(52 citation statements)
references
References 9 publications
2
45
2
1
Order By: Relevance
“…Another experimental performance study is that of Wittkopf et al [19]. In the frame of that study, the first zero-energy office building in Singapore used the 142.5 kWp p-Si grid-connected system on the roof of the building to meet its energy target.…”
Section: Introductionmentioning
confidence: 99%
“…Another experimental performance study is that of Wittkopf et al [19]. In the frame of that study, the first zero-energy office building in Singapore used the 142.5 kWp p-Si grid-connected system on the roof of the building to meet its energy target.…”
Section: Introductionmentioning
confidence: 99%
“…For PV system, measurements of the solar radiation, PV voltage and current are almost unavoidable. Depending on whether the PV system is stand-alone PV system (Benghanem, 2010;Forero et al, 2006;Gagliarducci et al, 2007;Krauter, 2004;Park et al, 2012;Ranhotigamage & Mukhopadhyay, 2011;Soler-Bientz et al, 2006) or a grid-connected PV system (Anwari et al, 2011;Ayompe et al, 2011;Boonmee, Plangklang, & Watjanatepin, 2009;Carullo & Vallan, 2012;López et al, 2012;Pietruszko & Gradzki, 2003;Wittkopf, Valliappan, Liu, Ang, & Cheng, 2012), a different sets of additional measurements are required. For the former, parameters related to battery and/or loads are usually needed; while for the latter, parameters related to the grid, i.e.…”
Section: Monitored Parametersmentioning
confidence: 99%
“…In (Park et al, 2012), Autobase is used for programming the PLC in the developed SCADA system. For numeric calculation and analysis, MATLAB (Benghanem, 2009b;Wittkopf et al, 2012) is a popular choice of software. System design software such as LabVIEW (Anwari et al, 2011;Benghanem, 2009a;Benghanem, 2010;Carullo & Vallan, 2012;Forero et al, 2006;Gagliarducci et al, 2007;López et al, 2012;Soler-Bientz et al, 2006) is commonly used, as it provides various comprehensive measurement and control tools in a single application package.…”
Section: Program Development Softwarementioning
confidence: 99%
“…Wittkopf et al [9] analyzed the performance of 142.5 kW P gridconnected BIPV systems installed on office buildings in Singapore by analyzing the measured values obtained over a period of 18 months using the International Electrotechnical Commission (IEC) standard 61,724, and they found that the average array yield was 3.86 h/d, and the resulting final yield was 3.12 h/d after the capture and system losses (0.58 h/d and 0.16 h/d, respectively) were deducted. The system and array efficiencies are 11.2% and 11.8%, respectively, and the nameplate PV module efficiency is 13.7%.…”