2008
DOI: 10.1515/cclm.2008.159
|View full text |Cite
|
Sign up to set email alerts
|

Analytical performance evaluation of the Cobas 6000 analyzer – special emphasis on trueness verification

Abstract: Considering the excellent precision data and the result equivalence for most assays, it can be concluded that Cobas 6,000 accommodates robust chemistry and immunochemistry, and has good potential for workstation consolidation in medium-sized laboratories.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
22
0
1

Year Published

2010
2010
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 39 publications
(24 citation statements)
references
References 11 publications
1
22
0
1
Order By: Relevance
“…That is sup por ted by re sul ts for wit hi n-run coeffi cie nt of va ria tion that is ge ne ral ly lower than 5% (exce pt for trig lyce ri des, cho les te rol, IgA and IgM) and for be twee n-day coeffi cie nt of va ria tion lower than 10% for all tes ted ana lytes (Tab le 2). Our re sul ts on va li da tion are con sis te nt wi th tho se pu blis hed by van Gam me ren et al (11). Al thou gh re sul ts are presen ted in diff e re nt man ner, da ta for to tal im precision can be com pa red, and no sig ni fi ca nt diff e rence be tween ob tai ned re sul ts is no ted (11).…”
Section: Discussionsupporting
confidence: 65%
“…That is sup por ted by re sul ts for wit hi n-run coeffi cie nt of va ria tion that is ge ne ral ly lower than 5% (exce pt for trig lyce ri des, cho les te rol, IgA and IgM) and for be twee n-day coeffi cie nt of va ria tion lower than 10% for all tes ted ana lytes (Tab le 2). Our re sul ts on va li da tion are con sis te nt wi th tho se pu blis hed by van Gam me ren et al (11). Al thou gh re sul ts are presen ted in diff e re nt man ner, da ta for to tal im precision can be com pa red, and no sig ni fi ca nt diff e rence be tween ob tai ned re sul ts is no ted (11).…”
Section: Discussionsupporting
confidence: 65%
“…The Cobas analyzer is known to be highly precise. 28,29 Tail blood was analyzed for HbA1C and BG on the Cobas 6000 analyzer and EBIO plus glucose analyzer (Eppendorf AG, Hamburg, Germany), respectively. Blood samples analyzed following the 3 week insulin/vehicle intervention were taken exactly 2 h after the morning NPH insulin/vehicle injection.…”
Section: Biochemical Analysesmentioning
confidence: 99%
“…Disease activity at the 15-year followup was assessed by Disease Activity Score 28-joint count (DAS28; that is, 0.56 √ tender joint count + 0.28 √ swollen joint count + 0.70 lnESR + 0.014 patient global). Serum samples were analyzed consecutively at the time of patient visit and CRP at followup was measured using the Cobas 6000 analyzer (range 1-250 mg/l) 22 .…”
Section: Rheumatologymentioning