2020
DOI: 10.1002/dta.2877
|View full text |Cite
|
Sign up to set email alerts
|

Analytical approaches applied to the analysis of apprehended formulations of anabolic androgenic steroids

Abstract: Anabolic androgenic steroids (AASs) comprise a class of synthetic androgens resulting from chemical modifications of testosterone, known for their illicit consumption, which can result inextensive side effects. Extraction procedures applied to the analysis of their formulations are still limited to a few methodologies, despite the increasing numbers of confiscations of AASs. In this sense, the aims of this work were to evaluate the extraction of active ingredients from formulations of anabolic agents using sol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(10 citation statements)
references
References 29 publications
0
10
0
Order By: Relevance
“…Fluoxymesterone, for instance, turns yellow in contact with concentrated sulfuric acid, light green (if cooled) in naphtol‐sulfuric acid solution, yellow in the Liebermann's test and yellow‐brown in Mandelin's test color differences of an anabolic agent in distinct spot tests may be associated to different mechanisms that occur in each colorimetric analysis and to the formulation. In the Liebermann's test color is formed by the reaction of the hydroxyl group in ring A with the reagents while in the Mandelin's test color is formed due to reactions with steroidal unsaturation (Berneira, Silva, et al, 2020; Chiong et al, 1992; Moffat et al, 2011).…”
Section: Analytical Techniquesmentioning
confidence: 99%
See 2 more Smart Citations
“…Fluoxymesterone, for instance, turns yellow in contact with concentrated sulfuric acid, light green (if cooled) in naphtol‐sulfuric acid solution, yellow in the Liebermann's test and yellow‐brown in Mandelin's test color differences of an anabolic agent in distinct spot tests may be associated to different mechanisms that occur in each colorimetric analysis and to the formulation. In the Liebermann's test color is formed by the reaction of the hydroxyl group in ring A with the reagents while in the Mandelin's test color is formed due to reactions with steroidal unsaturation (Berneira, Silva, et al, 2020; Chiong et al, 1992; Moffat et al, 2011).…”
Section: Analytical Techniquesmentioning
confidence: 99%
“…It is worth noting that besides increasing extraction efficiency, the use of microwave irradiation and ultrasound is aligned with several green chemistry principles as their usage decreases solvent and sample amounts and, thus, they are able to reduce energy consumption, waste generation, human exposure, and solvents released to the environment (Llompart et al, 2019). The higher extraction of yield of microwave irradiation compared to conventional extraction techniques was associated with the focused energy in the sample and the increased temperatures that are formed during the extraction process (Berneira, dos Santos, et al, 2020; Berneira, Silva, et al, 2020).…”
Section: Extraction and Clean‐up Approachesmentioning
confidence: 99%
See 1 more Smart Citation
“…Most of the published methods have employed laborious and time‐consuming techniques, which almost always require solvent extraction and/or derivatization steps. Among these techniques, we can mention ultra‐ and high‐performance liquid chromatography (UPLC and HPLC) with mass spectrometry or diode array UV detector, 9–12 gas chromatography coupled to mass spectrometry (GC–MS) or flame ionization detection (GC–FID), 8,12–14 differential scanning calorimetry (DSC), 15 and nuclear magnetic resonance ( 1 H NMR) spectroscopy 16 . Some articles have utilized techniques based on chemical images generated by coupling a microscope with a vibrational spectroscopic technique, such as attenuated total reflection Fourier transform infrared microspectroscopy (μATR‐FTIR) 4 and hyperspectral Raman spectroscopy 17 .…”
Section: Introductionmentioning
confidence: 99%
“…Oily samples are one of the most common forms of seized anabolic steroids, which are available for intravenous or intramuscular administration. This formulation is presented in lipophilic excipient, which provides slow release of the active ingredient into the circulation and prolongs its biological effect in the organism 8 . This form of anabolic steroid is the most challenging for chromatographic analysis, because the oil matrix is hard to remove even by tedious extraction processes, often demanding derivatization 23 …”
Section: Introductionmentioning
confidence: 99%