2022
DOI: 10.1002/jcla.24258
|View full text |Cite
|
Sign up to set email alerts
|

Analytical and clinical evaluation of DiaSorin Liaison® Calprotectin fecal assay adapted for serum samples

Abstract: This is an open access article under the terms of the Creat ive Commo ns Attri butio n-NonCo mmerc ial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 28 publications
0
3
0
1
Order By: Relevance
“…Calprotectin is a heterodimer formed by two proteins, S100A8 and S100A9, which are the most up-regulated proteins in rheumatoid arthritis [ 47 ]. Calprotectin can be measured in serum, plasma, and feces and exhibits potency as an inflammatory non-systemic biomarker [ 78 ]. Increased serum concentrations of calprotectin have been found in RA patients in contrast to healthy controls [ 78 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Calprotectin is a heterodimer formed by two proteins, S100A8 and S100A9, which are the most up-regulated proteins in rheumatoid arthritis [ 47 ]. Calprotectin can be measured in serum, plasma, and feces and exhibits potency as an inflammatory non-systemic biomarker [ 78 ]. Increased serum concentrations of calprotectin have been found in RA patients in contrast to healthy controls [ 78 ].…”
Section: Discussionmentioning
confidence: 99%
“…Calprotectin can be measured in serum, plasma, and feces and exhibits potency as an inflammatory non-systemic biomarker [ 78 ]. Increased serum concentrations of calprotectin have been found in RA patients in contrast to healthy controls [ 78 ]. A meta-analysis shows that blood calprotectin relates to disease risk, inflammation, and disease activity in RA patients [ 79 ].…”
Section: Discussionmentioning
confidence: 99%
“…This analyzer was designed for the quantification of fecal calprotectin so results are expressed in µg/g. Based on previous publication [ 9 ] a conversion factor of 2.5 was used to transform these units into ng/mL for the pleural fluid sample. The calibration curve was also transformed, being the measurement range of 12.50–2,000 ng/mL.…”
Section: Methodsmentioning
confidence: 99%
“…Este analizador fue originariamente diseñado para la cuantificación de calprotectina fecal, por lo que presenta los resultados en µg/g. Basándonos en un estudio previo [ 9 ], utilizamos un factor de conversión de 2,5 para transformar dichas unidades a ng/ml, para las muestras de líquido pleural. También se transformó la curva de calibración, siendo el rango de medida de 12,50–2000 ng/mL.…”
Section: Materiales Y Métodosunclassified