Analytic findings in the electroluminescence characterization of crystalline silicon solar cells

Abstract: The electroluminescence intensity from Si cells under the forward bias was found to have one to one quantitative agreement with the minority carrier diffusion length. Based on the diffusion equation and simple p-n diode model, the electroluminescence intensity was analyzed relative to the cell performance. Electroluminescence intensity is proportional to the product of the injected minority carrier density and the effective diffusion length. The diode ideality factor n can be deduced by measuring the electrolu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
51
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 113 publications
(51 citation statements)
references
References 4 publications
0
51
0
Order By: Relevance
“…Various methods such as photoluminescence (PL), 5 electroluminescence (EL), 6 electron beam induced current (EBIC), 7 and laser beam induced current (LBIC) 8 have been used for investigating solar cells. The PL method detects and images luminescence from a solar cell illuminated by light, and it can visualize the distribution of radiative defects and minority carrier lifetime in a solar cell.…”
mentioning
confidence: 99%
“…Various methods such as photoluminescence (PL), 5 electroluminescence (EL), 6 electron beam induced current (EBIC), 7 and laser beam induced current (LBIC) 8 have been used for investigating solar cells. The PL method detects and images luminescence from a solar cell illuminated by light, and it can visualize the distribution of radiative defects and minority carrier lifetime in a solar cell.…”
mentioning
confidence: 99%
“…The resultant EL emmision is in proportion to the total excess minority carrier density of the material [22]. The reduced minority carrier density regions can be spatially detected as lower intensity regions or dark spots, which can be easily visualised.…”
Section: Methodsmentioning
confidence: 99%
“…In particular, attention was paid to fill factor (FF) behaviors because an increase in series resistance and a decrease in shunt resistance markedly affect FF characteristics. Electroluminescence (EL) measurements 19) and photoluminescence (PL) measurements 20) were also carried out to detect visually the series resistance increase (by EL imaging) and the shunt resistance decrease (by PL imaging). The acetic acid concentration in the EVA encapsulant of the sample tested was measured by ion chromatography (IC) using an ultrapure water solvent solution in which acetic acid was eluted from the EVA encapsulant at approximately 90°C for 2 h.…”
Section: Experimental Methodsmentioning