2016
DOI: 10.1109/tdei.2016.006108
|View full text |Cite
|
Sign up to set email alerts
|

Analysis on the spectrum characteristic of corona Current and its relationship with Radio Interference on UHVDC transmission line

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 16 publications
0
8
0
Order By: Relevance
“…According to our previous research, the interfering signals mixed in the corona current include three types [27]: (i) the 100 Hz signal and its harmonic signals, which are produced due to incomplete inversion and rectification of the high-voltage generator. The amplitudes of these harmonic signals are relatively high when the frequency is within 600 Hz.…”
Section: Data Processing For Corona Currentmentioning
confidence: 99%
See 1 more Smart Citation
“…According to our previous research, the interfering signals mixed in the corona current include three types [27]: (i) the 100 Hz signal and its harmonic signals, which are produced due to incomplete inversion and rectification of the high-voltage generator. The amplitudes of these harmonic signals are relatively high when the frequency is within 600 Hz.…”
Section: Data Processing For Corona Currentmentioning
confidence: 99%
“…For the above three types of signals, different methods are adopted to eliminate their influences in this paper. The specific noise reduction process will not be discussed in detail since it is not the key point of this paper, and relative research could refer to the work in [27,28]. Fig.…”
Section: Data Processing For Corona Currentmentioning
confidence: 99%
“…However, the existing research mainly focuses on the measurement of single frequency points (0.5MHz or 1MHz) or multiple frequency points of radio interference. This measurement method belongs to the frequency domain measurement method [7][8][9][10][11]. The measurement results reflect the IOP Publishing doi:10.1088/1742-6596/2384/1/012031 2 comprehensive effect of radio interference over a period of time, but it is difficult to reflect the intrinsic characteristics of radio interference [12].…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, researches in recent years showed that the frequency domain characteristics of corona current are closely related with a variety of corona effects, such as audible noise [27][28][29][30]. In [29], the correlation between corona current spectrum and audible noise spectrum below 20 kHz was studied, and it has been found that the variation laws of audible noise and corona current are very similar in the band of 2-20 kHz.…”
Section: Introductionmentioning
confidence: 99%
“…In [26], it was pointed out that, the 1/3 octave power spectrum (1/3 OPS) of corona current, which can be used to calculate corona inception voltage, increases with voltage raise of HVDC transmission lines. In [27], the change rule of corona current spectrum was found in the frequency range of 0.15–4 MHz. In [1], the self‐correlation of corona current spectrum was analysed in the band of 5–20 kHz.…”
Section: Introductionmentioning
confidence: 99%