1998
DOI: 10.1021/jp9619853
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of X-ray Absorption Spectra of Some Nickel Oxycompounds Using Theoretical Standards

Abstract: X-ray absorption spectra have been measured for NiO, β-Ni(OH) 2 , R-Ni(OH) 2 , LiNiO 2 , and KNiIO 6 samples, which contain nickel with valency in the range 2-4. Information on the local structure and nature of bonding of nickel compounds has been derived using theoretical standards generated with the FEFF code. The Ni K-edge energy was found to shift to higher values by about 1.5 eV per unit change in valency of nickel. The energy of the preedge peak (generally attributed to the transition from the 1s core st… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

15
80
1

Year Published

2007
2007
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 111 publications
(96 citation statements)
references
References 54 publications
15
80
1
Order By: Relevance
“…3b), which show a clear energy shift of the edge of +2.5(3) eV and some subtle differences at higher energy [18]. The sign of the energy shift is fully consistent with an electron-rich Ni1 site [19,20] and is uniquely determined from the data. In addition, the absolute scaling of the peak intensities ensures an accurate and reliable determination of the magnitude of the edge shift.…”
Section: ′′supporting
confidence: 58%
“…3b), which show a clear energy shift of the edge of +2.5(3) eV and some subtle differences at higher energy [18]. The sign of the energy shift is fully consistent with an electron-rich Ni1 site [19,20] and is uniquely determined from the data. In addition, the absolute scaling of the peak intensities ensures an accurate and reliable determination of the magnitude of the edge shift.…”
Section: ′′supporting
confidence: 58%
“…The peaks at 8351, 8365, and 8398 eV in β-Ni(OH) 2 /rGO were consistent with those of reported β-Ni(OH) 2 . [ 33 ] The shoulder at 8336 eV in Ni-NiO/NrGO indicates the presence of metallic Ni species. Meanwhile, the EXAFS for β-Ni(OH) 2 /rGO is also very different to those of Ni-NiO/N-rGO (Figure 3 f).…”
Section: Resultsmentioning
confidence: 99%
“…A linear background was first fitted to the pre-edge region and subtracted before the XANES spectra were normalized to one at energy 8360 eV. The XANES spectrum of sample 1 resembled that of the Ni foil but showed a maximum typical for oxides indicating that nickel was in metallic and oxidized forms (Mansour & Melendres, 1998). Spectra of samples 2-4 showed smoother features, which indicated that Ni was in weakly ordered nanoparticles.…”
Section: Resultsmentioning
confidence: 99%