1999
DOI: 10.1016/s0006-3495(99)77220-6
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Vertical Fluorescence Resonance Energy Transfer from the Surface of a Small-Diameter Sphere

Abstract: Fluorescence resonance energy transfer (FRET) measurements have been used to analyze fluorophore separations in a number of varying geometries, including small particles and extended surfaces. This study focuses on the geometry created by a donor extended above the surface of a small sphere (radius < R0), where the acceptors are integrated into the sphere surface. The model of this geometry was based on an amphipathic molecule with its lipophilic region integrated into a detergent micelle and its hydrophilic r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1999
1999
2010
2010

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 36 publications
0
3
0
Order By: Relevance
“…The linear relationship between the logarithms of absorption coefficient and the particle diameter was found suggesting that the particle concentrations were correctly provided . According to Jones et al, the total surface area of the differently sized particles should be kept constant to yield the same surface coverage and quenching . However, we observed different quenching efficacies for the particles.…”
Section: Resultsmentioning
confidence: 55%
See 1 more Smart Citation
“…The linear relationship between the logarithms of absorption coefficient and the particle diameter was found suggesting that the particle concentrations were correctly provided . According to Jones et al, the total surface area of the differently sized particles should be kept constant to yield the same surface coverage and quenching . However, we observed different quenching efficacies for the particles.…”
Section: Resultsmentioning
confidence: 55%
“…35 According to Jones et al, the total surface area of the differently sized particles should be kept constant to yield the same surface coverage and quenching. 36 However, we observed different quenching efficacies for the particles. Thus, we selected a number of particles for each particle size giving equal background signal (no BSA sample in the assay) to the comparative study.…”
Section: Resultsmentioning
confidence: 60%
“…To evaluate the FRET efficiency between a pointlike donor and acceptor molecules distributed over a two-dimensional surface, averaging over every allowed configuration and over the statistical distribution of the number of acceptors per micelle is required. We essentially adapted the calculations of Jones et al (18) to our model and refer the reader to this publication and to Wolber et al (19) for further details.…”
Section: Modelmentioning
confidence: 99%