2018
DOI: 10.2514/1.b36895
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Unsteady Gas Temperature Measurements in the Appendix Gap of a Stirling Engine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 10 publications
0
8
0
Order By: Relevance
“…Furthermore, the width of the appendix gap, which was determined based on the analytical models by Rios [15] and Berchowitz [17], amounts to 1.4 mm in the case of the hot displacer because of the scaling. Due to this large width, it was possible to equip the gap section with fine-wire thermocouple probes for high-speed gas temperature measurements within a subsequent project [32]. These probes are radially adjustable over the entire gap width by a micrometer head.…”
Section: Seal Design Modification In the Convertible Laboratory-scale Machinementioning
confidence: 99%
See 3 more Smart Citations
“…Furthermore, the width of the appendix gap, which was determined based on the analytical models by Rios [15] and Berchowitz [17], amounts to 1.4 mm in the case of the hot displacer because of the scaling. Due to this large width, it was possible to equip the gap section with fine-wire thermocouple probes for high-speed gas temperature measurements within a subsequent project [32]. These probes are radially adjustable over the entire gap width by a micrometer head.…”
Section: Seal Design Modification In the Convertible Laboratory-scale Machinementioning
confidence: 99%
“…Furthermore, the machine was equipped with a series of wall thermocouples along the hot cylinder wall, as well as a third pressure transducer attached to the hot cylinder volume, thus ensuring a precise evaluation of the indicated work. Detailed information concerning the new instrumentation is provided in [32]. To ensure similarity with respect to thermal conduction and appendix gap losses, thermostat jackets are attached to the hot and cold displacers.…”
Section: Seal Design Modification In the Convertible Laboratory-scale Machinementioning
confidence: 99%
See 2 more Smart Citations
“…Considering that the hydrodynamic entry length in laminar flow may extend to more than 50 times the hydraulic diameter, this assumption will probably apply to a small section around the center of the gap only, if at all. So, Sauer and Kühl performed experimental investigations to verify the predictions by the analytical model [20,21]. For this purpose, an experimental machine was used, the design of which had been downsized to laboratory scale by application of similarity-based scaling rules [22].…”
Section: Experimental Investigation Of the Appendix Gap Lossmentioning
confidence: 99%