Analysis of Timing Effect on Flow Field and Pulsation in Vertical Axial Flow Pump

Abstract: Vertical axial flow pump device has the characteristics of large flow and low head, which is widely used in pumping station projects with head of 3–9 m. In order to study the influence of the timing effect of the impeller relative flow channel and guide vane on the flow field and pulsation in the axial flow pump device, the whole flow channel of the vertical axial flow pump device was taken as the research object. The reliability of the numerical simulation was verified by physical model test. The flow field c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 30 publications
0
8
0
Order By: Relevance
“…The energy loss inside the guide vane mainly comes from the eddy current inside the guide vane. With the increase of flow rate, the flow pattern inside the guide vane becomes better [ 27 ], and the energy loss decreases with the decrease of eddy current. With the increase of K Q , the EPR inside the guide vane moves to the trailing edge of the guide vane, and the EPR reduces, which is consistent with the change of energy loss shown in Figure 7 .…”
Section: Results and Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…The energy loss inside the guide vane mainly comes from the eddy current inside the guide vane. With the increase of flow rate, the flow pattern inside the guide vane becomes better [ 27 ], and the energy loss decreases with the decrease of eddy current. With the increase of K Q , the EPR inside the guide vane moves to the trailing edge of the guide vane, and the EPR reduces, which is consistent with the change of energy loss shown in Figure 7 .…”
Section: Results and Analysismentioning
confidence: 99%
“…Therefore, when K Q = 0.52–0.62, the EPR distribution of the elbow is mainly focused on the turning point and transfers to the elbow outlet. In Sec.3–Sec.5, the EPR distribution is asymmetric under various K Q , which is related to the uneven flow distribution at the guide vane outlet and the uneven flow distribution caused by the residual circulation at the guide vane outlet [ 27 ].…”
Section: Results and Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…The boundary conditions in the calculation domain are set as shown in Table 2. The time parameter setting of unsteady numerical simulation of the vertical axial flow pump device can be used for the transient calculation of the axial flow pump device (Yang et al, 2021b).…”
Section: Calculation Methods and Boundary Conditionsmentioning
confidence: 99%
“…The three-dimensional model of the vertical axial flow pump device is shown in Figure 1. The geometric dimensions of the vertical axial flow pump device can be seen in the study by Yang et al (2021b).…”
Section: Simulation Modelmentioning
confidence: 99%