2012
DOI: 10.1007/s10765-012-1225-x
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Thermal-Conductivity Measurement Data from International Comparison of National Laboratories

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(19 citation statements)
references
References 6 publications
0
19
0
Order By: Relevance
“…the manufacturer formulation [6,7]. As will be shown later, the effective thermal conductivities for Materials (6) and (7) were lower than Materials (4) and (9), presumably because graphite reduces the radiative heat-transfer contribution. Table 3 summarizes the thermal test conditions and the number of measurements conducted for each comparison.…”
Section: Methodsmentioning
confidence: 87%
See 2 more Smart Citations
“…the manufacturer formulation [6,7]. As will be shown later, the effective thermal conductivities for Materials (6) and (7) were lower than Materials (4) and (9), presumably because graphite reduces the radiative heat-transfer contribution. Table 3 summarizes the thermal test conditions and the number of measurements conducted for each comparison.…”
Section: Methodsmentioning
confidence: 87%
“…In the standard double sided mode of operation, the two cold plates are maintained at equivalent temperatures Guarded-hot-plate schematic, double-sided mode of operation for a specimen pair. 7 For consistency, the temperature data in this paper are presented in kelvin, requiring conversion, where necessary, of the source data recorded in °C.…”
Section: Apparatusmentioning
confidence: 99%
See 1 more Smart Citation
“…The general objective of the technical work is to consolidate the traceability and capabilities [5][6][7] for the measurement of thermal conductivity by Guarded Hot Plate (GHP) in European emerging NMIs (WP3):  Transfer the knowledge from experienced laboratories toward the NMIs of the Central and Western Balkans countries, through training courses, tutorials and workshops.  Implement thermal conductivity measurements by the GHP method in emerging NMIs by participating in an inter-laboratory comparison whose main objectives are to assess the coherency of measurements among involved laboratories.…”
Section: Thermal Conductivitymentioning
confidence: 99%
“…The general objective of the technical work is to consolidate the traceability and capabilities [5][6][7] for the measurement of thermal conductivity by Guarded Hot Plate (GHP) in emerging European NMIs through the activities below:…”
Section: Thermal Conductivitymentioning
confidence: 99%