2016
DOI: 10.1016/j.ijrefrig.2016.02.004
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the spatiotemporal temperature fluctuations inside an apple cool store in response to energy use concerns

Abstract: This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain. 0Analysis of the spatiotemporal temperature fluctu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
35
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 46 publications
(37 citation statements)
references
References 25 publications
1
35
0
Order By: Relevance
“…Monitoring postharvest fruit temperature history of fresh fruits is thus essential to evaluate the efficacy of existing commercial cold-chain unit operations but also to explore new cooling strategies. Typical examples of such recent cooling strategies are flow reversal for forced-air precoolers (Ferrua and Singh, 2009), ambient loading for refrigerated containers (Defraeye et al, 2015b) and intermittent operation of cooling fans in cold storage rooms and refrigerated containers (Ambaw et al, 2016;Lukasse et al, 2011;Thompson, 2004). Fruit temperature measurements are also essential to evaluate and develop new ventilated bulk packaging (Gruyters et al, 2017;O'Sullivan et al, 2016;Wu et al, 2017).…”
Section: Introductionmentioning
confidence: 99%
“…Monitoring postharvest fruit temperature history of fresh fruits is thus essential to evaluate the efficacy of existing commercial cold-chain unit operations but also to explore new cooling strategies. Typical examples of such recent cooling strategies are flow reversal for forced-air precoolers (Ferrua and Singh, 2009), ambient loading for refrigerated containers (Defraeye et al, 2015b) and intermittent operation of cooling fans in cold storage rooms and refrigerated containers (Ambaw et al, 2016;Lukasse et al, 2011;Thompson, 2004). Fruit temperature measurements are also essential to evaluate and develop new ventilated bulk packaging (Gruyters et al, 2017;O'Sullivan et al, 2016;Wu et al, 2017).…”
Section: Introductionmentioning
confidence: 99%
“…The air side heat transfer coefficient of the cooling unit (hc, W m -2 K -1 ) was represented by the Colburn ja factor (Bejan, 1993;Tso et al, 2006). Figure 3 shows the experimental results obtained from Ambaw et al (2016) of the air temperature dynamics of the tubular heat exchanger during the "off" phase of the cooling cycle. Since the initial temperature of Tc was not known a best fit was used, and the inlet air temperature during the "off" phase of the cooling cycle was approximated with an exponential curve which corresponds well with the experimental results and model (1).…”
Section: Model Of the Temperature Control With Different Differential Rangesmentioning
confidence: 99%
“…It should be noted that a continuous airflow was used in this study. By allowing the air ventilator fans to stop working, it is possible to reduce the energy consumption as was pointed out by East et al (2013) and Ambaw et al (2016).…”
Section: Net Energy Expenditure Of Coolingmentioning
confidence: 99%
See 2 more Smart Citations