2014 16th International Conference on Harmonics and Quality of Power (ICHQP) 2014
DOI: 10.1109/ichqp.2014.6842776
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the harmonic distortion impact of photovoltaic generation in Brazilian residential networks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(18 citation statements)
references
References 9 publications
0
17
0
1
Order By: Relevance
“…Many studies are being carried out globally to investigate the impact of residential rooftop solar PV systems on distribution networks. Previous researchers have evaluated these impacts on voltage rise (Begovic, et al, 2012, Tonkoski, et al, 2012, Ali, et al, 2012, voltage fluctuations, voltage unbalance (Begovic, et al 2012, Chandra, et al 2013 and higher levels of harmonics (Torquato, et al, 2014, Chidurala, et al, 2016.…”
Section: Introductionmentioning
confidence: 99%
“…Many studies are being carried out globally to investigate the impact of residential rooftop solar PV systems on distribution networks. Previous researchers have evaluated these impacts on voltage rise (Begovic, et al, 2012, Tonkoski, et al, 2012, Ali, et al, 2012, voltage fluctuations, voltage unbalance (Begovic, et al 2012, Chandra, et al 2013 and higher levels of harmonics (Torquato, et al, 2014, Chidurala, et al, 2016.…”
Section: Introductionmentioning
confidence: 99%
“…at sunrise and sunset [5][6][7]. Analysis of a residential PV application reveals that critical cases must be considered: the network operating under a light load, the PV system connected at a low short-circuit level point and operating with a leading power factor [6,8]. Observation of the PQ effect on a solar PV connected to an unbalanced distribution system showed that the PV inverter supplied balanced currents into a grid and resulted in voltage fluctuations at the point of common coupling (PCC) [9].…”
Section: Introductionmentioning
confidence: 99%
“…Recently, the use of lighting devices have been changing from incandescent lamps to power electronic base lamps. Variation of power affects the harmonic emission a little when the output is large [8,10,11]. The nonlinear loads generate less harmonic content if the supply voltage is distorted (attenuation effect) [10].…”
Section: Introductionmentioning
confidence: 99%
“…Several studies and analysis were carried out by researchers over the PQ issues in MG power network at various conditions. [5] THD analysis was performed through simulation in a typical Photo Voltaic (PV) integrated low voltage distribution network at various conditions. THD voltage and current levels were found high in the following conditions; penetration of PV at higher level, far end feeder, low load, and load operates at leading power factor.…”
Section: Introductionmentioning
confidence: 99%