1982
DOI: 10.1016/s0022-5223(19)39044-0
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the design and dynamics of aortic bioprostheses in vivo

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

1988
1988
2016
2016

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(5 citation statements)
references
References 27 publications
0
5
0
Order By: Relevance
“…This interrelation between supra-aortic ridge displacement and leaflet motion greatly determines the stress on the leaflets. 24,25 We found no significant differences in the distensibility parameters at the supra-aortic ridge level between the operative techniques and control subjects. These normal values of distensibility probably decrease leaflet stresses 24,25 and thus serve to contribute to the durabil- ity of valve function.…”
Section: Discussionmentioning
confidence: 57%
See 1 more Smart Citation
“…This interrelation between supra-aortic ridge displacement and leaflet motion greatly determines the stress on the leaflets. 24,25 We found no significant differences in the distensibility parameters at the supra-aortic ridge level between the operative techniques and control subjects. These normal values of distensibility probably decrease leaflet stresses 24,25 and thus serve to contribute to the durabil- ity of valve function.…”
Section: Discussionmentioning
confidence: 57%
“…24,25 We found no significant differences in the distensibility parameters at the supra-aortic ridge level between the operative techniques and control subjects. These normal values of distensibility probably decrease leaflet stresses 24,25 and thus serve to contribute to the durabil- ity of valve function. In addition these data also provide some evidence that the inclusion technique does not lead to increased stiffness by the double wall as suggested by Ross.…”
Section: Discussionmentioning
confidence: 57%
“…Geometry and dynamic changes of aortic bioprostheses have been studied for the most part experimentally. 40,41 3D echocardiography could make comparable studies in humans possible. 3.…”
Section: Limitationsmentioning
confidence: 99%
“…14). Design parameters of the stented bioprostheses and the configuration of the leaflets (20). as well as the rigidity (8.…”
Section: Introductionmentioning
confidence: 99%
“…and height (12) ofthe commissural stents are primary factors for unphysiological stresses. A reduction of stresses on the leaflets by modification of the design in imitation of the natural aortic valve apparatus should theoretically improve their hemodynamic function and durability (20).…”
Section: Introductionmentioning
confidence: 99%