Analysis of the Accuracy and Robustness of the Leap Motion Controller

Abstract: Abstract:The Leap Motion Controller is a new device for hand gesture controlled user interfaces with declared sub-millimeter accuracy. However, up to this point its capabilities in real environments have not been analyzed. Therefore, this paper presents a first study of a Leap Motion Controller. The main focus of attention is on the evaluation of the accuracy and repeatability. For an appropriate evaluation, a novel experimental setup was developed making use of an industrial robot with a reference pen allowin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
348
1
11

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 773 publications
(364 citation statements)
references
References 23 publications
4
348
1
11
Order By: Relevance
“…(Bachmann, Weichert, & Rinkenauer, 2015). Thereby, a deviation between a desired 3D position and the average measured positions below 0.2 mm has been obtained for static setups and of 1.2 mm for dynamic setups, minimal in reducing the LMC outcomes since the involuntary hand tremor amplitude varies between 0.4 mm ± 0.2 mm (Weichert, Bachmann, Rudak, & Fisseler, 2013 …”
Section: Functioningmentioning
confidence: 98%
“…(Bachmann, Weichert, & Rinkenauer, 2015). Thereby, a deviation between a desired 3D position and the average measured positions below 0.2 mm has been obtained for static setups and of 1.2 mm for dynamic setups, minimal in reducing the LMC outcomes since the involuntary hand tremor amplitude varies between 0.4 mm ± 0.2 mm (Weichert, Bachmann, Rudak, & Fisseler, 2013 …”
Section: Functioningmentioning
confidence: 98%
“…The device has been shown to be an accurate and robust sensor [15], and its validity and reliability to measure the 15-second G-R test is reported in our previous article. This study extends the proof of concept work by reporting normative values for young healthy individuals regarding both the frequency of cycles as well as the magnitude of motion during a 15-second test and a 3-minute test.…”
Section: Introductionmentioning
confidence: 93%
“…The operation range varies from 25 to 650 millimetres above the controller. The average accuracy of the sensor is about 0.7 millimetres [14]. The Leap Motion controller does not perform any computations, therefore the acquisition and processing speed depend strongly on the used PC specification.…”
Section: Data Acquisition and Feature Extractionmentioning
confidence: 99%