2002
DOI: 10.1016/s0009-2541(02)00162-6
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of sulfides in whole rock matrices by elemental analyzer–continuous flow isotope ratio mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
44
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 90 publications
(45 citation statements)
references
References 4 publications
0
44
0
Order By: Relevance
“…For sulfur isotope measurements, whole-rock powders were analyzed using elemental analyzer-continuous flow isotope ratio mass spectrometry (Studley et al, 2002). Sample powders (1 mg to 150 mg) were placed in tin cups with 1 to 5 mg of V 2 O 5 and combusted at ~1800 o C, with a reactor column temperature of 1010 o C. Analyses of SO 2 were made using a Finnigan MAT 252 stable isotope ratio mass spectrometer at Indiana University, with the results reported in standard delta notation relative to CDT (Canyon Diablo Troilite).…”
Section: Methodsmentioning
confidence: 99%
“…For sulfur isotope measurements, whole-rock powders were analyzed using elemental analyzer-continuous flow isotope ratio mass spectrometry (Studley et al, 2002). Sample powders (1 mg to 150 mg) were placed in tin cups with 1 to 5 mg of V 2 O 5 and combusted at ~1800 o C, with a reactor column temperature of 1010 o C. Analyses of SO 2 were made using a Finnigan MAT 252 stable isotope ratio mass spectrometer at Indiana University, with the results reported in standard delta notation relative to CDT (Canyon Diablo Troilite).…”
Section: Methodsmentioning
confidence: 99%
“…The resulting silver sulfide precipitate was powdered, along with acanthite minerals. These samples were combined with excess V 2 O 5 and combusted to SO 2 and analyzed conventionally for d 34 S using elemental analyzer-isotope ratio mass spectrometry (Studley et al, 2002). Standard deviations (1s) were 0.1% for known standards and precipitated silver sulfide, and B1% for acanthite minerals, presumably due to inhomogeneities between subsampled crystals.…”
Section: Nanosims Analysis and Isotopic Calibrationmentioning
confidence: 99%
“…The BaSO 4 precipitate was washed and centrifuged three times using distilled, deionized water from a Millipore gradient Mili-Q water filtration system with a QuantumEX and Q-Gard-2 dual-filtration system. Sulfur isotope ratios for BaSO 4 and CdS were determined using an EA1110 elemental analyzer coupled to a Finnigan Mat 252 isotope ratio mass spectrometer via a ConFlo II split interface (57). Isotope data are reported as the ␦ 34 S per mille deviation from the Vienna Cañon Diablo Troilite (VCDT) calculated by using equation 3:…”
mentioning