2020 Fourth International Conference on Inventive Systems and Control (ICISC) 2020
DOI: 10.1109/icisc47916.2020.9171115
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Stability in IEEE 14 Bus System using ETAP Software

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 9 publications
0
2
0
Order By: Relevance
“…He et al [39] examined the TS of a DC distribution network-connected distributed photovoltaic generator and generated a variable parameter control approach. Siva et al [40] built a hybrid PV/Wind system for TS analysis, power flow analysis, and P, Q correction in an IEEE 14 Bus system to decrease transmission losses, and fuel cost, and improve transmission line stability. Using a hybrid PSO-BFOA controller based on swarm optimization, the efficacy of wind and PV was evaluated to suppress and moderate global chaotic oscillations in a multi-machine system [41].…”
Section: Figure 6 Pv Inverter Modelmentioning
confidence: 99%
“…He et al [39] examined the TS of a DC distribution network-connected distributed photovoltaic generator and generated a variable parameter control approach. Siva et al [40] built a hybrid PV/Wind system for TS analysis, power flow analysis, and P, Q correction in an IEEE 14 Bus system to decrease transmission losses, and fuel cost, and improve transmission line stability. Using a hybrid PSO-BFOA controller based on swarm optimization, the efficacy of wind and PV was evaluated to suppress and moderate global chaotic oscillations in a multi-machine system [41].…”
Section: Figure 6 Pv Inverter Modelmentioning
confidence: 99%
“…The phasor measurement units (PMUs) placed at different locations generally at the ends of the line or at different bus locations. The optimal placement of PMU [14] is decided by different algorithms like genetic algorithm, particle swarm optimization (PSO), and artificial bee colony (ABC). Phasor measuring units [15] are the devices which measure the magnitude, frequency and phase of any voltage or current of a grid system synchronized with universal time coordinate (UTC).…”
Section: Phasor Measuring Unitmentioning
confidence: 99%
“…Technology with PV and wind turbine installation techniques on a connected roof directly on the power grid using early streamer emission (ESE) technology in reducing the occurrence of lightning strikes. Therefore, before carrying out the installation, a more optimal relay coordination accuracy test is carried out with simulations and scenarios on the distribution network using electrical transient analyzer program (ETAP) software and also MATLAB software to see PV energy conversion [25]- [27]. The reliability of the installation of this technology will certainly increase consumer confidence in the installation of renewable energy, this is of course considering that the material and operational costs of the installation are very high so that it must be protected [28]- [30].…”
mentioning
confidence: 99%