2014 16th International Power Electronics and Motion Control Conference and Exposition 2014
DOI: 10.1109/epepemc.2014.6980643
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of space vector modulation technique in inverter-fed fault-tolerant induction motor drive

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
5
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…It is larger for θ = 0 • or θ = 60 • (maximum voltage amplitudeû max (u dc , 0) = 2 3 u dc ) than for θ = 30 • (minimum voltage amplitudê u max (u dc , π/6) = 1 √ 3 u dc ). Invoking trigonometric identities leads to the expression ofû max in (14) by only considering the first sector of the voltage hexagon, i.e. θ = θ ∈ 0 • , 60 • .…”
Section: A Standard Control System (Field-oriented Control)mentioning
confidence: 99%
See 2 more Smart Citations
“…It is larger for θ = 0 • or θ = 60 • (maximum voltage amplitudeû max (u dc , 0) = 2 3 u dc ) than for θ = 30 • (minimum voltage amplitudê u max (u dc , π/6) = 1 √ 3 u dc ). Invoking trigonometric identities leads to the expression ofû max in (14) by only considering the first sector of the voltage hexagon, i.e. θ = θ ∈ 0 • , 60 • .…”
Section: A Standard Control System (Field-oriented Control)mentioning
confidence: 99%
“…Note that, in the first sector, θ coincides with θ. Then, by using the auxiliary phase angle θ as defined in (14), the generalized formula for the available amplitude ûmax is obtained for all other sectors of the voltage hexagon.…”
Section: A Standard Control System (Field-oriented Control)mentioning
confidence: 99%
See 1 more Smart Citation
“…Depending on a motor drive system purpose, a faulty transistor can be swap out with a redundant switch so that a total drive functionality is maintained or a faulty inverter leg is isolated from an electric motor and then additional circuits are activated between a motor and an inverter. From an economic point of view, the second approach is more beneficial than the first one but does not sustain a nominal drive performance, namely a linear inverter voltage modulation range is significantly reduced, so a nominal speed of a full-loaded drive cannot be obtained [10]. Nevertheless, in some applications, a remedial action which consider a decrease of a motor drive functionality in favor of economical profits is recommended.…”
Section: Introductionmentioning
confidence: 99%
“…Unfortunately, an implementation of the low-cost FTCM is usually difficult because of some hardware limitations that cannot be neglected in a control algorithm. In case of the four-switch inverter topology, which is considered in this paper, a main problem constitutes a capacitor voltage unbalance in DC-link of a power converter [5,10].…”
Section: Introductionmentioning
confidence: 99%