2022
DOI: 10.1039/d2ay01394k
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of solid uranium particulates on cotton swipes with an automated microextraction-ICP-MS system

Abstract: An automated microextraction method coupled to an inductively coupled plasma – mass spectrometer (ICP-MS) was developed for the direct analysis of solid uranium particulates on the surface of cotton swipes....

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 43 publications
0
9
1
Order By: Relevance
“…The Plate Express was re-engineered in-house at Oak Ridge National Laboratory with an automated X – Y stage and a camera. The modifications to the original Plate Express have previously been described . The experimental setup can be seen in Figure .…”
Section: Materials and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The Plate Express was re-engineered in-house at Oak Ridge National Laboratory with an automated X – Y stage and a camera. The modifications to the original Plate Express have previously been described . The experimental setup can be seen in Figure .…”
Section: Materials and Methodsmentioning
confidence: 99%
“…The modifications to the original Plate Express have previously been described. 35 The experimental setup can be seen in Figure 1. The swipe was placed in a polyether ether ketone (PEEK) sample holder on top of a square of Teflon.…”
Section: Microextraction−icp−msmentioning
confidence: 99%
See 1 more Smart Citation
“…A collaboration between this laboratory and the Oak Ridge National Laboratory (ORNL) introduced a simple method of extracting solution residues and particulates from standard cotton swipes for the determination of uranium and plutonium isotope ratios. 32 The approach was based on the use of the Advion (Ithaca, NY) plate express as a means of solutionmicroextraction from a cloth substrate and transporting the eluate rst to a liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source, 32 and more recently to ICP sources, [33][34][35][36] for MS detection. The device was originally designed as a means of extracting organic species from thin layer chromatography (TLC) plates, 37,38 for their transport to electrospray ionization (ESI) sources for qualitative analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Following the initial demonstration with the LS-APGD/Orbitrap coupling, more extensive reports from Manard and co-workers have described the performance of the swipe sampling methodology towards U and Pu isotopic analysis on a variety of ICP-MS instrument platforms. [33][34][35][36] The microextraction with plasma MS detection has proven to be simple and quantitative, requiring virtually zero sample preparation, with LODs, precision, and sensitivity that is quite sufficient for most U/Pu nuclear forensics applications.…”
Section: Introductionmentioning
confidence: 99%