2007
DOI: 10.1016/j.jvir.2007.01.006
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Simulated Angiographic Procedures. Part 2: Extracting Efficiency Data from Audio and Video Recordings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
10
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(11 citation statements)
references
References 26 publications
1
10
0
Order By: Relevance
“…This is the first study of IR simulation that has accurately discriminated across expertise on a number of performance metrics. It is therefore an important addition to existing research into IR simulation that has to date failed to discriminate expertise, although differences across expertise have been reported [11,12]. Length of time to complete a simulated procedure has previously been found to discriminate expertise [6,19] and was confirmed here.…”
Section: Discussionsupporting
confidence: 66%
See 1 more Smart Citation
“…This is the first study of IR simulation that has accurately discriminated across expertise on a number of performance metrics. It is therefore an important addition to existing research into IR simulation that has to date failed to discriminate expertise, although differences across expertise have been reported [11,12]. Length of time to complete a simulated procedure has previously been found to discriminate expertise [6,19] and was confirmed here.…”
Section: Discussionsupporting
confidence: 66%
“…laparascopic surgery [7], colonoscopy [8] and anaesthetics [9]. However, within IR no simulator has met this standard [5,6,10], with validation studies typically failing to discriminate accurately between experts and novices [11], although differences have been observed [12]. Length of time to complete procedures on simulators is a frequently reported expertise discriminator [6] but there is a worrying lack of emphasis on the number of errors made or other clinically relevant parameters.…”
mentioning
confidence: 99%
“…By contrast to our study, previous studies that used multivideo recordings in fluoroscopic interventions to evaluate intraprocedural decision-making, focused on third-person perspective, not taking advantage of first-person experience nor paying attention to how limitations in the environment affect performance [26,27].…”
Section: Discussionmentioning
confidence: 59%
“…Our methods of both observation and metric measurement have been described as reliable [17]. However, the machine-generated measures of performance are relatively limited-procedure time, fluoroscopy time, measurement of contrast and balloon or stent position-and are crude measures of performance.…”
Section: Discussionmentioning
confidence: 99%