2004
DOI: 10.1016/j.talanta.2004.04.011
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of riboflavin in beer by capillary electrophoresis/blue light emitting diode (LED)-induced fluorescence detection combined with a dynamic pH junction technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
42
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 75 publications
(43 citation statements)
references
References 23 publications
0
42
0
Order By: Relevance
“…One of the main applications of CE for vitamins [23,[104][105][106][107] has been the determination of flavins [104,105], due to their native fluorescence and good solubility in water. Thus, an inexpensive method for the routine analysis of riboflavin in beer by MEKC using blue light emitting diode induced fluorescence detection was described by Su et al [104].…”
Section: Vitaminsmentioning
confidence: 99%
See 1 more Smart Citation
“…One of the main applications of CE for vitamins [23,[104][105][106][107] has been the determination of flavins [104,105], due to their native fluorescence and good solubility in water. Thus, an inexpensive method for the routine analysis of riboflavin in beer by MEKC using blue light emitting diode induced fluorescence detection was described by Su et al [104].…”
Section: Vitaminsmentioning
confidence: 99%
“…Thus, an inexpensive method for the routine analysis of riboflavin in beer by MEKC using blue light emitting diode induced fluorescence detection was described by Su et al [104]. The detection limit was down to 1 ng/ml, allowing the determination of riboflavin in 12 different types of commercial beer at concentrations ranging from 130 to 280 ng/mL.…”
Section: Vitaminsmentioning
confidence: 99%
“…As previously reported [11,12], RF in aqueous medium presents two excitation maxima at 8 approximately 368 and 440 nm, and a fluorescence emission maximum at 524 nm. The pH changes in the range 4-8 did not produce any significant modifications in the fluorescence signal [33]. Because the pH of the analyzed urine samples were between 5 and 7, it was not adjusted.…”
Section: Preliminary Studiesmentioning
confidence: 99%
“…The standard method for riboflavin determination in food is the fluorimetric method, defined by Association of Official Analytical Chemists. 6 The other used techniques are spectrophotometry, 7-9 chemiluminescence, 10 capillary electrophoresis, [11][12][13] and the most frequently used HPLC. [14][15][16][17] These methods have demonstrated good sensitivity and selectivity, but their implementation requires specialised expensive equipment and the procedures may be rather complicated and time-consuming.…”
Section: Introductionmentioning
confidence: 99%