2019
DOI: 10.1007/s00170-019-04102-5
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of red blood cell deformability using parallel ladder electrodes in a microfluidic manipulation system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 30 publications
0
11
0
Order By: Relevance
“…Second, a major barrier to physical measurement of RBC deformability is that these methods are prohibitively difficult, time consuming, and require specialized equipment. 35,57,58 In contrast, microscope systems are ubiquitous in both research and clinical laboratories. Finally, while there are several methods available for physical measurement of RBC deformability, there are no accepted standards by which to compare studies.…”
Section: Discussionmentioning
confidence: 99%
“…Second, a major barrier to physical measurement of RBC deformability is that these methods are prohibitively difficult, time consuming, and require specialized equipment. 35,57,58 In contrast, microscope systems are ubiquitous in both research and clinical laboratories. Finally, while there are several methods available for physical measurement of RBC deformability, there are no accepted standards by which to compare studies.…”
Section: Discussionmentioning
confidence: 99%
“…An approach using electrode-based microfluidic systems has studied RBC stretching using dielectrophoretic forces. This also elucidates the relationship between the dielectrophoretic forces, voltage, and electrode gap distances at the single-cell level [159]. A pressure gradient-based approach is also beneficial in the assessment of cell rigidity.…”
Section: Deformation Of Single Erythrocytes In Microchannelsmentioning
confidence: 93%
“…Figure 10B shows the critical pressure for driving a RBC through a contracting microfluidic channel [160]. and Figure 10C shows the system structure of RBC deformability measurements using parallel ITO electrodes in a microfluidic manipulation system [159].…”
Section: Deformation Of Single Erythrocytes In Microchannelsmentioning
confidence: 99%
See 1 more Smart Citation
“…In contrast, the traditional DEP method requires a series of separate processes such as video recording, manual selection, manual measurement, etc. After accumulating the time of all the measurement processes, the measurement data per minute is less than 1 ( Li et al., 2019 ). Second, the automatic measurement method we proposed can obtain effective measurement data of more than 1000 cells in one experiment, compared to less than 100 for traditional DEP methods ( Du et al., 2014 ), which is an order of magnitude difference.…”
Section: Introductionmentioning
confidence: 99%