2017
DOI: 10.21037/jtd.2017.11.04
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of pulmonary pure ground-glass nodule in enhanced dual energy CT imaging for predicting invasive adenocarcinoma: comparing with conventional thin-section CT imaging

Abstract: Background: To investigate the value of dual energy computed tomography (DECT) parameters (including iodine concentration and monochromatic CT numbers) for predicting pure ground-glass nodules (pGGNs) of invasive adenocarcinoma (IA).Methods: A total of 55 resected pGGNs evaluated with both unenhanced thin-section CT (TSCT) and enhanced DECT scans were included. Correlations between histopathology [adenocarcinoma in situ (AIS), minimally IA (MIA), and IA] and CT scan characteristics were examined. CT scan and c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

3
14
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(19 citation statements)
references
References 26 publications
3
14
0
2
Order By: Relevance
“…Due to the different scanning parameters, the tube current, pixel spacing, and slice thickness of CT image was variety. Whether and how these scanning parameters affect the scheme performance have not been investigated in this study (29).…”
Section: Discussionmentioning
confidence: 99%
“…Due to the different scanning parameters, the tube current, pixel spacing, and slice thickness of CT image was variety. Whether and how these scanning parameters affect the scheme performance have not been investigated in this study (29).…”
Section: Discussionmentioning
confidence: 99%
“…Third, the majority of selected cases in this study were elderly people with a mean age of 61.5 years, and younger patients should be included in future studies. Fourth, monochromatic CT number was measured only enhanced monochromatic spectral CT imaging at the energy level 40 and 70 keV based on previous studies, ignoring the other keV selection. Fifth, quantifying microvessel densities previously described in a previous study were not included in this study.…”
Section: Discussionmentioning
confidence: 99%
“…Spectral CT imaging has been applied in several of the studies on pulmonary nodules. Most researchers believe that quantitative parameters of spectral CT imaging have certain advantages in the differential diagnosis of benign and malignant pulmonary nodules . There is no study testing the association between the spectral CT imaging parameters and the PD‐L1 expression in lung adenocarcinoma.…”
Section: Introductionmentioning
confidence: 99%
“…Кроме того, выбрав область интереса (ROI) на йодной карте, можно измерить количество йода в ткани в мг/см 2 (или концентрацию йода в мг/мл в вокселе), тем самым количественно оценить накопление контрастного вещества, не прибегая к анализу усредненных значений рентгеновской плотности в единицах Хаунсфилда. Поскольку материал-специфические изображения йода (йодные карты) не зависят от присущего ткани затухания, они являются более надежным показателем контрастного усиления по сравнению с оценкой значений рентгеновской плотности при традиционных многофазных контрастных исследованиях [26,[30][31][32].…”
unclassified
“…Применение ДЭКТ при диагностике очаговых образований печени. В большом количестве исследований показано значение низкоэнергетических ВМИ и йодных карт для идентификации опухолей различной локализации [2,3,6,7,14,18,22,27,32,[34][35][36][37]. Работы, посвященные дифференциальной диагностике образований печени, немногочисленны, и, главным образом, связаны с анализом концентрации йода в различных очагах.…”
unclassified