Analysis of Power Converter Losses in Vector Control System of a Self–Excited Induction Generator

Abstract: This paper provides analysis of losses in the hysteresis-driven three-phase power converter with IGBTs and free-wheeling diodes. The converter under consideration is part of the self-excited induction generator (SEIG) vector control system. For the analysis, the SEIG vector control system is used in which the induction generator iron losses are taken into account. The power converter losses are determined by using a suitable loss estimation algorithm reported in literature. The chosen algorithm allows the powe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 30 publications
(39 reference statements)
0
5
0
Order By: Relevance
“…By contrasting the created FL voltage controllers' performance with that of the optimally tuned traditional PI controller, their effectiveness is assessed. Various combinations of rotor speed, load, and DC voltage are analyzed on both an experimental and simulation level [23].…”
Section: Seig; Nonlinear Control; Predictive Control; Ripples; Dynami...mentioning
confidence: 99%
See 1 more Smart Citation
“…By contrasting the created FL voltage controllers' performance with that of the optimally tuned traditional PI controller, their effectiveness is assessed. Various combinations of rotor speed, load, and DC voltage are analyzed on both an experimental and simulation level [23].…”
Section: Seig; Nonlinear Control; Predictive Control; Ripples; Dynami...mentioning
confidence: 99%
“…𝑖 𝑞𝑓,𝑘+1 = 𝑖 𝑞𝑓,𝑘 + ( 𝑑𝑖 𝑞𝑓,𝑘 𝑑𝑡 )𝑇 𝑠 (23) where the two components ( 𝑑𝑖 𝑑𝑓,𝑘 𝑑𝑡 )and ( 𝑑𝑖 𝑞𝑓,𝑘 𝑑𝑡 ) can be obtained from equations ( 18) and ( 19). According to the grid scheme in Fig.…”
Section: Control Technique For Grid Side Convertermentioning
confidence: 99%
“…When the load is in a state close to short circuit and idle running, the power naturally drops. The voltage in the case of a short circuit also decreases, and in idle running, it increases, but not as much as with the conventional circuits of autonomous inverters [7,[19][20][21][22]. These results have been used to plot the load characteristic of AI with ED in case of battery charging.…”
Section: Experimental Investigationsmentioning
confidence: 99%
“…Due to the increase of power electronic converters in different devices, an especially important factor for optimizing converters is power quality, which can be described in terms of its thermal characteristics. Indeed, previous researches have clarified the relationship of converter performance and quality in terms of heat loss [2][3][4]. Furthermore, Usui and Ishiko presented a simple approach for the thermal design of an IGBT module practised only in steady state operation [5].…”
Section: Introductionmentioning