2003
DOI: 10.1109/tns.2003.817297
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of position-dependent Compton scatter in scintimammography with mild compression

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
11
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(13 citation statements)
references
References 1 publication
2
11
0
Order By: Relevance
“…This lower scatter content, as compared to the high scatter and torso contribution near the chest wall, corresponds to lower image noise, which would enhance SNR. This finding agrees with some literature related to the scatter distribution of nuclear breast images and the importance of energy resolution (Pani et al 1998, Williams et al 2000, Williams et al 2003). However, with the enhancement only observed with deep-seated tumours, a case for ER offering little to no benefit to breast imaging can also be made (Hruska and O’Connor 2006, Hruska and O’Connor 2008).…”
Section: Discussionsupporting
confidence: 93%
“…This lower scatter content, as compared to the high scatter and torso contribution near the chest wall, corresponds to lower image noise, which would enhance SNR. This finding agrees with some literature related to the scatter distribution of nuclear breast images and the importance of energy resolution (Pani et al 1998, Williams et al 2000, Williams et al 2003). However, with the enhancement only observed with deep-seated tumours, a case for ER offering little to no benefit to breast imaging can also be made (Hruska and O’Connor 2006, Hruska and O’Connor 2008).…”
Section: Discussionsupporting
confidence: 93%
“…Although that schedule was not always availchest wall edge of the compression paddle. Gamma imaging can be performed in list mode to permit postacquisition scatter correction ( 35 ) and/or extraction of information about tracer dynamics, if desired. MBI tomosynthesis reconstruction is performed by using an expectation maximization algorithm.…”
Section: Dmt Scanner Descriptionmentioning
confidence: 99%
“…Williams et al previously demonstrated the varying scatter contribution in the energy spectra as a function of distance from the chest wall. 17 Although not explored in this work, it may be beneficial to apply a standard energy window at the chest wall and the wider energy window for pixels away from the chest wall edge.…”
Section: Discussionmentioning
confidence: 99%