2021
DOI: 10.1016/j.radphyschem.2020.109157
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of phosphorous content in cancer tissue by synchrotron micro-XRF

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 37 publications
0
9
0
Order By: Relevance
“…The endothelial cell membrane is a physiological barrier to prevent interstitial Pi diffusion even intratumoral Pi concentration is higher than that of normal tissue and serum. [19,20] If this barrier has not been perturbed, intratumoral Pi will not be exhausted by sevelamer positioned in the blood vessels. As we confirmed, oral administra-tion of sevelamer only exhausts plasma Pi partially without deprivation of intratumoral Pi.…”
Section: Tumor Necrosis Is the Essential Index To Evaluate Therapeuti...mentioning
confidence: 99%
“…The endothelial cell membrane is a physiological barrier to prevent interstitial Pi diffusion even intratumoral Pi concentration is higher than that of normal tissue and serum. [19,20] If this barrier has not been perturbed, intratumoral Pi will not be exhausted by sevelamer positioned in the blood vessels. As we confirmed, oral administra-tion of sevelamer only exhausts plasma Pi partially without deprivation of intratumoral Pi.…”
Section: Tumor Necrosis Is the Essential Index To Evaluate Therapeuti...mentioning
confidence: 99%
“…They monitored the intensity excitation beam before and after it passed through the sample (and sample substrate) in order to calculate the transmission factor for each pixel at the mean energy E M of the polychromatic beam. By comparison with the mean transmission factor of a reference position, it is possible to calculate the transmission factor of the sample at each incident energy: 22 T ( E ) = e − μ S ( E ) ρ S t S Here ρ S is the sample density, t S is the sample thickness and μ S ( E ) is the mass attenuation coefficient for the sample at incident energy E .…”
Section: Methodsmentioning
confidence: 99%
“…The incoming microbeam excitation X-ray spectrum on the sample was determined through a spectral reconstruction technique, based on the scattering pattern of a thin standard plastic material. 22…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Falchini et al 25 developed quantitative elemental imaging approaches for application to the important topic of cancer research. Their quantitative strategy was based on the fundamental parameter method which considered excitation by a polychromatic incident microbeam and took into account sample matrix effects.…”
Section: Synchrotron and Large-scale Facilitiesmentioning
confidence: 99%