2006
DOI: 10.1002/mas.20093
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of pesticides in water by liquid chromatography‐tandem mass spectrometric techniques

Abstract: Pesticide residues continue to be the focus of many environmental studies, and the number of articles describing the development of more advanced, multiresidue analytical methodologies does not decline. The use of liquid chromatography-mass spectrometry based on single quadrupole or ion trap analyzers is consolidated for this purpose. The implementation, in the near future, of more sophisticated mass analyzers, such as triple quadrupole and hybrid quadrupole-time-of-flight is anticipated for routine analysis. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
55
0
11

Year Published

2007
2007
2016
2016

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 84 publications
(66 citation statements)
references
References 55 publications
(102 reference statements)
0
55
0
11
Order By: Relevance
“…The use of different types of detectors helps in the identification and quantification of compounds. 16 It is widely used nowadays due to its advantages in relation to gas chromatography (GC), since there is a trend towards the use of more polar pesticides (they are considered more readily degradable 17,18 and cannot be directly analyzed using GC at volatilization temperatures). Consequently, there is a need to develop methods using HPLC to determine these compounds and their metabolites.…”
mentioning
confidence: 99%
“…The use of different types of detectors helps in the identification and quantification of compounds. 16 It is widely used nowadays due to its advantages in relation to gas chromatography (GC), since there is a trend towards the use of more polar pesticides (they are considered more readily degradable 17,18 and cannot be directly analyzed using GC at volatilization temperatures). Consequently, there is a need to develop methods using HPLC to determine these compounds and their metabolites.…”
mentioning
confidence: 99%
“…Method LOD values were below the maximum levels permitted for pesticides in surface waters, which are of 1 µg L -1 for individual pesticides and of 5 µg L -1 for total pesticides in water that will be destined for human consumption after treatment (Kuster et al, 2006). The analytical methods were validated and demonstrated to be accurate and efficient for the quantification of the selected herbicides.…”
Section: Sample Preparation and Determination Of Herbicides Residues mentioning
confidence: 97%
“…Além disso, a acidificação da fase móvel também auxilia na ionização dos analitos. 39,40 Ao se empregar a espectrometria de massas em série, através do modo de aquisição de monitoramento de reações múltiplas (MRM), é possível quantificar compostos que coeluem através do monitoramento das transições íon precursor -íon produto de cada substância. Assim, LC-MS/MS assegura a identificação com maior exatidão do que quando ela é feita apenas com base nas características de retenção das substâncias analisadas, como ocorre nas outras técnicas de detecção cromatográficas.…”
Section: Avaliação Da Vazão Da Fase Móvelunclassified