2009
DOI: 10.1016/j.fuel.2008.08.014
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of oxygen-containing polycyclic aromatic compounds by gas chromatography with atomic emission detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…Aczel et al also identified the sulfur compounds present in a heavy hydrogenated fraction (≥700 °F): C n H 2 n –4 S (MW 126, 4 × 10 –3 ), C n H 2 n –16 S (MW 226, 3 × 10 –3 ), C n H 2 n +8 S (MW 231, 2 × 10 –3 ), and C n H 2 n –20 S (MW 252, 5 × 10 –3 ). Wu et al , did not detect by ESI FT-ICR mass spectroscopy on sulfur-containing class, which may have been related to the low ionization efficiency of sulfur by ESI.…”
Section: Coal Liquefaction Chemical Productsmentioning
confidence: 98%
See 2 more Smart Citations
“…Aczel et al also identified the sulfur compounds present in a heavy hydrogenated fraction (≥700 °F): C n H 2 n –4 S (MW 126, 4 × 10 –3 ), C n H 2 n –16 S (MW 226, 3 × 10 –3 ), C n H 2 n +8 S (MW 231, 2 × 10 –3 ), and C n H 2 n –20 S (MW 252, 5 × 10 –3 ). Wu et al , did not detect by ESI FT-ICR mass spectroscopy on sulfur-containing class, which may have been related to the low ionization efficiency of sulfur by ESI.…”
Section: Coal Liquefaction Chemical Productsmentioning
confidence: 98%
“…Bartle et al used a GC–AED to detect the dibenzofurans in the coal oil derived from Spanish coal, which had been liquefied at 400 °C with a process-derived hydrogenated solvent. Sumbogo et al , also used this technique to identify phenol, alkylphenols, alkylbenzofurans, and alkyldibenzofurans in the liquid products of the gas oil fraction derived from Tanito Harum and South Banko coals (SBCL).…”
Section: Coal Liquefaction Chemical Productsmentioning
confidence: 99%
See 1 more Smart Citation
“…The GC (× GC)-effluent is directed into a He plasma chamber where all elements are atomized and excited. When the atoms transition from the excited to the relaxed state, radiation at a characteristic wavelength for every element is released and detected ( Tranchida and Mondello, 2019 , Bartle et al, 2009 ).…”
Section: State-of-the-art Molecular Characterization Techniquesmentioning
confidence: 99%
“…With GC-AED, the elements were in groups on the condition that close emission line wavelengths and the same scavenger gases were used [27]. For this reason, three sequential chromatographic runs were required to obtain chromatograms for C, H and O.…”
Section: Optimization Of Aed Parametersmentioning
confidence: 99%