2009 10th International Conference on Electrical Power Quality and Utilisation 2009
DOI: 10.1109/epqu.2009.5318848
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of operation of voltage transformers during interruptions and dips of primary voltage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 1 publication
0
6
0
Order By: Relevance
“…The obtained results of electronic voltage transducers operation in conditions of voltage dips and interruptions of measured voltage were compared to similar measurements obtained from the previously studied inductive voltage transformers [6]. Voltage transformer A with two secondary windings (2000 V / 100 V / 100 V, 0,5 class) was described in details in the scientific works [6,7].…”
Section: Results For Inductive Voltage Transformersmentioning
confidence: 99%
See 2 more Smart Citations
“…The obtained results of electronic voltage transducers operation in conditions of voltage dips and interruptions of measured voltage were compared to similar measurements obtained from the previously studied inductive voltage transformers [6]. Voltage transformer A with two secondary windings (2000 V / 100 V / 100 V, 0,5 class) was described in details in the scientific works [6,7].…”
Section: Results For Inductive Voltage Transformersmentioning
confidence: 99%
“…Voltage transformer A with two secondary windings (2000 V / 100 V / 100 V, 0,5 class) was described in details in the scientific works [6,7]. During laboratory studies inductive voltage transformer type UDZ 24 (2000 V / 100 V, 0,5 class) was also tested [6][7][8].…”
Section: Results For Inductive Voltage Transformersmentioning
confidence: 99%
See 1 more Smart Citation
“…It is possible to evaluate the impulse voltage distribution in transformer winding and the related winding response to a standard full wave and to a clipped wave, especially at the ends of the coil [9]. Another important aspect is the value of the load and its power factor; in fact the impedance increase at the secondary winding involves a reduction of harmonics disturbances influence [10]. A measurement laboratory survey has been conducted by the Authors in recent years.…”
Section: Introductionmentioning
confidence: 99%
“…Ref. [ 30 ] represents another frequency characterization of VTs, while [ 31 ] analyzes the frequency characterization of VT under network interruptions. For LPCTs, [ 32 ] introduces a new Rogowski coil design to measure a wide pulse current.…”
Section: Introductionmentioning
confidence: 99%