2015
DOI: 10.1109/tla.2015.7350030
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Minimum Modulation for the 9-Level Multilevel Inverter in Asymmetric Structure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(11 citation statements)
references
References 12 publications
0
10
0
1
Order By: Relevance
“…In APOD all the carrier waveforms has same frequency but each adjacent carrier wave are phase shifted. The IPD, POD, APOD waveforms with carrier and modulated waveform [11] is shown in figure 3,4 and 5. The number of carrier waves will be based upon the subtraction of number of voltage levels by 1 ie., in propose paper levels to be attained is nine, then number of carriers is 9-1=8.This paper focuses on POD based SPWM because it diminishes the harmonics at a lower modulation values.…”
Section: Control Strategymentioning
confidence: 99%
“…In APOD all the carrier waveforms has same frequency but each adjacent carrier wave are phase shifted. The IPD, POD, APOD waveforms with carrier and modulated waveform [11] is shown in figure 3,4 and 5. The number of carrier waves will be based upon the subtraction of number of voltage levels by 1 ie., in propose paper levels to be attained is nine, then number of carriers is 9-1=8.This paper focuses on POD based SPWM because it diminishes the harmonics at a lower modulation values.…”
Section: Control Strategymentioning
confidence: 99%
“…Salah satu dari metode pensaklarannya adalah Phase Disposition Pulse Width Modulation (PDPWM) [11] [12]. Metode PDPWM adalah salah satu strategi modulasi dari perpotongan antara gelombang segitiga dengan gelombang sinus yang menghasilkan pulsa pembangkit [13] [14].…”
Section: Pendahuluanunclassified
“…Each cell considers the use of photovoltaic panels with different levels of DC voltage under the ratio 9:3:1. It is possible to find in the literature other asymmetry proportions for this converter [29,30]; however, it has been shown that the used relation minimizes the redundant states [8,9] and, therefore, generates less harmonic content in the resulting waveforms of the converter. Due to the asymmetric distribution of the voltages, HPC handles, at most, one of the total power of the converter, while the rest is distributed between the MPC and LPC modules.…”
Section: Introductionmentioning
confidence: 99%