Ocean Drilling Program Technical Notes 2000
DOI: 10.2973/odp.tn.29.2000
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Major and Trace Elements in Rocks, Sediments, and Interstitial Waters by Inductively Coupled Plasma–Atomic Emission Spectrometry (ICP-AES)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
152
0
1

Year Published

2011
2011
2016
2016

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 159 publications
(153 citation statements)
references
References 4 publications
0
152
0
1
Order By: Relevance
“…Samples were prepared using the Li Metaborate fusion technique following Murray et al (2000), which is preferred over HF digestion because it is the only technique that allows the complete dissolution of sediment samples containing refractory minerals such as zircon (Sholkovitz, 1990;Murray et al, 2000;Huang et al, 2007). Sample preparation consisted in (δ 15 N), were measured at the UCDavis Stable Isotope Facility by continuous flow isotope ratio mass spectrometry (CF-IRMS; 20-20 SERCON mass spectrometer) after sample combustion to CO 2 and N 2 at 1000°C in an on-line elemental analyzer (PDZEuropa ANCA-GSL).…”
Section: Inorganic Geochemistrymentioning
confidence: 99%
“…Samples were prepared using the Li Metaborate fusion technique following Murray et al (2000), which is preferred over HF digestion because it is the only technique that allows the complete dissolution of sediment samples containing refractory minerals such as zircon (Sholkovitz, 1990;Murray et al, 2000;Huang et al, 2007). Sample preparation consisted in (δ 15 N), were measured at the UCDavis Stable Isotope Facility by continuous flow isotope ratio mass spectrometry (CF-IRMS; 20-20 SERCON mass spectrometer) after sample combustion to CO 2 and N 2 at 1000°C in an on-line elemental analyzer (PDZEuropa ANCA-GSL).…”
Section: Inorganic Geochemistrymentioning
confidence: 99%
“…Both auxiliary gas and nebulizer flow rate amounted to 1.0 L/min, water sample uptake of 0.8 mL/min. Depending on the element, the low limit detection varied from a few ppb to ppm with 3% of uncertainty (Murray et al 2000, Oliveira & Sarkis 2001). The water sample of five liters of volume was reduced to nearly one liter by evaporation at 80°C, then the radium isotopes were co-precipitated together with barium carrier as a sulfate compound.…”
Section: Analytical Techniquesmentioning
confidence: 99%
“…The general method for shipboard ICP-AES analysis of samples is described in Murray et al (2000) and the user manuals for new shipboard instrumentation with modifications as indicated. Samples and standards were diluted 1:20 using 2% HNO 3 for trace element analyses (B, Mn, Fe, Sr, and Ba) and 1:200 for major element analyses (Na, K, Ca, and Mg).…”
Section: Inductively Coupled Plasma-emission Spectrometrymentioning
confidence: 99%
“…Analytical protocols are summarized below. In many cases, these protocols are based on those of Gieskes et al (1991), Murray et al (2000), and the IODP user manuals for new shipboard instrumentation, with modifications as indicated. However, as described in the following subsections, in many cases the instrumentation and protocols used during Expedition 329 supersede those cited above.…”
Section: Magnetostratigraphymentioning
confidence: 99%