2006
DOI: 10.1080/00387010500531266
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Heavy Metals in Scalp Hair Samples of Hypertensive Patients by Conventional and Microwave Digestion Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
53
0

Year Published

2007
2007
2015
2015

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 78 publications
(55 citation statements)
references
References 33 publications
0
53
0
Order By: Relevance
“…Blanks and standard solutions were prepared in a similar acid matrix. The validity and efficiency of the MWD method were checked with certified values of human hair NCSZC 81002b, Clincheck® control-lyophilized human whole blood, Virginia tobacco leaves (ICHTJ-ctaVTL-2) and with those obtained from conventional wet acid digestion method (Table 5; Afridi et al 2006).…”
Section: Microwave-assisted Acid Digestionmentioning
confidence: 99%
See 1 more Smart Citation
“…Blanks and standard solutions were prepared in a similar acid matrix. The validity and efficiency of the MWD method were checked with certified values of human hair NCSZC 81002b, Clincheck® control-lyophilized human whole blood, Virginia tobacco leaves (ICHTJ-ctaVTL-2) and with those obtained from conventional wet acid digestion method (Table 5; Afridi et al 2006).…”
Section: Microwave-assisted Acid Digestionmentioning
confidence: 99%
“…The main advantage of microwave-assisted sample pretreatment is its requirement of small amount of mineral acids and a reduction in the production of nitrous vapors (Divrikli et al 2006;Soylak et al 2007). Microwave systems keep blank levels low because only small volumes of reagents are required and allow more samples to be processed per hour than conventional digestion systems (Afridi et al 2006;.…”
Section: Introductionmentioning
confidence: 99%
“…After cutting, each sample was washed with diluted Triton X-100: samples were then rinsed with distilled water and then with deionized water. The samples were then rinsed three times with acetone (Afridi et al, 2006). The sam-ples were then dried in an oven at 75 ± 5 °C for 2 h. Dried samples were stored separately in polyethylene bags.…”
Section: Collection Of Scalp Hair Samplesmentioning
confidence: 99%
“…The main advantage of microwave-assisted samples pretreatment is its requirement of small amount of mineral acids and a reduction in the production of nitrous vapors. Microwave systems keep blank levels low because only small volumes of reagents are required and allow more samples to be processed per hour than conventional digestion systems (Afridi et al, 2006). As seen in the literature, the alterations in trace and toxic element concentrations in the scalp hair samples of RA patients are inconsistent and, to our knowledge, there are no available reports of the understudy elemental levels in smoker and nonsmokers RA patients.…”
mentioning
confidence: 99%
“…The main advantage of microwave-assisted samples pre-treatment is its requirement of small amount of mineral acids and a reduction in the production of nitrous vapors. Microwave systems keep blank levels low because only small volumes of reagents are required and allow more samples to be processed per hour than conventional digestion systems [30].…”
Section: Introductionmentioning
confidence: 99%