2006
DOI: 10.1016/j.renene.2005.01.012
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
62
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 217 publications
(73 citation statements)
references
References 7 publications
5
62
0
Order By: Relevance
“…For transverse ribs, growth in the friction factor is almost twice the increase in heat transfer. The best performance was recorded for ribs with rectangular section in the range of the studied parameters [11,19,26]. Another important criterion, which has not been investigated enough, is that the rib height should not a ect the ow out of the laminar sublayer [6,19].…”
Section: E Ect Of the Cross Section Of The Roughnessmentioning
confidence: 99%
See 2 more Smart Citations
“…For transverse ribs, growth in the friction factor is almost twice the increase in heat transfer. The best performance was recorded for ribs with rectangular section in the range of the studied parameters [11,19,26]. Another important criterion, which has not been investigated enough, is that the rib height should not a ect the ow out of the laminar sublayer [6,19].…”
Section: E Ect Of the Cross Section Of The Roughnessmentioning
confidence: 99%
“…The choice of a two-dimensional geometry is based on the results of a numerical analysis by Chaube [19], who conducted two 2D and 3D analyses and compared the results with the experimental results of Karwa [11]. 3D analysis was performed with 1,203 million cells and the 2D one was carried out with 113, 006 cells.…”
Section: Geometry Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…These equations for incompressible streams can be written as follows. [24][25][26][27][28][29][30] :…”
Section: Governing Equationsmentioning
confidence: 99%
“…A critical review of literatures on rib roughened air duct reveals that very few studies are used CFD. 6,[24][25][26][27][28][29][30] To the best of our knowledge, no such type of CFD study has been reported on an artificially roughened air duct with V-shaped ribs combined with dimple ribs. The purpose of this work was to investigate fluid flow and heat transfer characteristics of a three-dimensional rectangular duct of an air duct with V with dimpled ribs by adopting the CFD approach.…”
Section: Introductionmentioning
confidence: 99%