2007 Australasian Universities Power Engineering Conference 2007
DOI: 10.1109/aupec.2007.4548035
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of harmonic distortion levels on a distribution network

Abstract: Abstract--It is generally acknowledged that harmonic distortion levels on distribution networks are steadily increasing due to the proliferation of non-linear loads. While customer complaints relating to harmonic distortion levels are relatively uncommon, and measured levels are typically well within the limits specified by national regulations and international standards, the increasing trend may mean that more active management by utilities will soon be required.Effective management of harmonic distortion le… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…While the discreet disturbances of harmonic distortion may not cause immediate and easily-observed impacts, it can cause some equipment to malfunction, and result in additional power losses in both customer and network equipment [17]. As harmonic levels change considerably from one week to another, it is very difficult to assess the long-term evolution of harmonic levels only from measurements carried out over a short period [1].…”
Section: Discussionmentioning
confidence: 99%
“…While the discreet disturbances of harmonic distortion may not cause immediate and easily-observed impacts, it can cause some equipment to malfunction, and result in additional power losses in both customer and network equipment [17]. As harmonic levels change considerably from one week to another, it is very difficult to assess the long-term evolution of harmonic levels only from measurements carried out over a short period [1].…”
Section: Discussionmentioning
confidence: 99%
“…The observed characteristics of the signal, f(t) is extracted using convolution integral given in Equation. (5).…”
Section: Density Function Of Prolonged Interruption and Under-voltagementioning
confidence: 99%
“…In another work which studied probability distribution of PQ data with special interest on the locations and occurrence time of disturbances. An Auckland real-life power data installed in over 30 monitoring sites has been surveyed by Vector Ltd since 1999 [5].…”
Section: Introductionmentioning
confidence: 99%
“…The results of their analysis are presented in numerous publications. Most of them consider low-and medium-voltage networks [1]- [4]. It is found out that the harmonic conditions in the electrical networks represent a random phenomenon.…”
Section: Introductionmentioning
confidence: 99%