2016
DOI: 10.1016/j.exer.2016.05.013
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of foveal characteristics and their asymmetries in the normal population

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
18
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 17 publications
(23 citation statements)
references
References 31 publications
1
18
0
Order By: Relevance
“…In the initial model, a single peripheral point was clustered together with the central four points corresponding with the fovea, which is inconsistent with an a priori assumption that the foveal pit is anatomically distinct from the rest of the retina. 44 Thus, in developing the final model, the central four locations corresponding to the fovea were masked and the data were reanalyzed, resulting in the reassignment of the aforementioned peripheral point with no other change in the classification. The ISODATA algorithm and statistical analysis provided the maximum number of statistically separable classes.…”
Section: Methodsmentioning
confidence: 99%
“…In the initial model, a single peripheral point was clustered together with the central four points corresponding with the fovea, which is inconsistent with an a priori assumption that the foveal pit is anatomically distinct from the rest of the retina. 44 Thus, in developing the final model, the central four locations corresponding to the fovea were masked and the data were reanalyzed, resulting in the reassignment of the aforementioned peripheral point with no other change in the classification. The ISODATA algorithm and statistical analysis provided the maximum number of statistically separable classes.…”
Section: Methodsmentioning
confidence: 99%
“…As pointed out in Ref. 51, p. 5, instead of using of the highest point of the foveal rim for this purpose, it is more advantageous to solve the equation E Q -T A R G E T ; t e m p : i n t r a l i n k -; e 0 0 5 ; 3 2 6 ; 2 8 8…”
Section: Definition Of the Foveal Region Within The B-scansmentioning
confidence: 99%
“…Based on these segmentations, we provide an automated determination of the central fovea region. 50,51 Automated measurements of mean choroidal thickness are given for this and two adjacent 1 mm regions, as defined in more detail in Sec. 2.6.…”
Section: Introductionmentioning
confidence: 99%
“…In our approach, an optically homogeneous tissue with a thickness of 250 μm and a refractive index of n retina = 1.370 at 555 nm wavelength with an Abbe's number of 50.23 was assumed for the retinal layer [1,12]. Thus, the length of the vitreous was reduced accordingly.…”
Section: Optical Simulation Basismentioning
confidence: 99%
“…Because of the refractive index step between the retinal tissue and vitreous, the fovea defines an optically effective interface with aspherical characteristics, which influences the ray propagation to the receptor layer buried about 250 μm within the retinal layers [1]. In principle, two basic foveal shapes can be distinguished [2].…”
Section: Introductionmentioning
confidence: 99%