2018
DOI: 10.1016/j.engstruct.2018.08.010
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of flexural and shear resistance of ultra high performance fiber reinforced concrete beams without stirrups

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
32
0
5

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 66 publications
(39 citation statements)
references
References 43 publications
2
32
0
5
Order By: Relevance
“…On the other side it was observed that ACI 318–11 code predicts close to experimental values but higher than CSA A23.3–04 and IS456‐2000 codes due to the fact that ACI considers less factor of safety for materials when compared to other two codes for effective use of material strength. Similar test results on beams without stirrups obtained by different authors 26–28 have been compared with theoretical values of same codes used in present study and shown in Table 8. It was observed that theoretical ultimate moment values calculated for their work, ACI 318–11 code predicts higher values compared to other two codes due to above said reason.…”
Section: Resultssupporting
confidence: 55%
“…On the other side it was observed that ACI 318–11 code predicts close to experimental values but higher than CSA A23.3–04 and IS456‐2000 codes due to the fact that ACI considers less factor of safety for materials when compared to other two codes for effective use of material strength. Similar test results on beams without stirrups obtained by different authors 26–28 have been compared with theoretical values of same codes used in present study and shown in Table 8. It was observed that theoretical ultimate moment values calculated for their work, ACI 318–11 code predicts higher values compared to other two codes due to above said reason.…”
Section: Resultssupporting
confidence: 55%
“…They were tested in a specially designed setup outside the furnace, under simple supports and a similar loading configuration as applied during the fire test, ie, two point loads, applied on the top face of the beam through a displacement controlled actuator. A displacement rate of 2 mm per minute was adopted in these residual strength tests …”
Section: Experimental Studymentioning
confidence: 99%
“…Ever since the beginning of the usage of reinforced concrete structures, various experimental studies have been conducted by the researchers on the basis of element. Numerous experimental studies have been conducted on reinforced concrete beams [18,[23][24][25][26][27][28][29][30][31][32][33][34]. These studies aimed to determine the shear resistance by using PP fibers used in reinforced concrete structures.…”
Section: Introductionmentioning
confidence: 99%